background image

Novar R/W reader with keypad, s.m.

Item no. 026421

P31116-10-002-00

10.12.2004

Sales and delivery in
accordance with our terms
of sale and delivery

Mounting and Connection Instructions

Mounting and Connection Instructions - Novar R/W

026421

reader with keypad

14

1.

Safety notes

Read the instructions carefully and thoroughly before installing the device and putting it into
operation. They contain important information on assembly, programming and operation.
The device is a state-of-the-art product. Only use the device:

- In accordance with regulations and
- When it is in a technically correct state
- In accordance with technical data.

The manufacturer is not responsible for damage that is caused by use not in accordance with regulations.
Installation, programming as well as maintenance and repair work may only be carried out by
authorized, skilled personnel.
Soldering and connection work should only be carried out inside the entire system when it is
deenergized.
Soldering work should only be carried out using a temperature-controlled soldering bit that is
galvanically separated from the power supply.
Observe the VDE safety instructions as well as the regulations of the local power supply company.

Do not use the reader in a potentially explosive environment or in rooms with metal or
plastic decomposing vapours.

Wipe housing and keypad

Cleaning

with soft lint-free dry cloth, or one that has been lightly

dampened with water. Abrasive cleaners or chemicals of any kind will damage or
discolour the surface of the housing.

Table of Contents

Page

1.

Safety notes ..............................................................................................................................14

2.

General ......................................................................................................................................15

3.

Functional description .............................................................................................................16

4.

5.

Connection diagram.................................................................................................................18

6.

Start-up......................................................................................................................................19

8.

..............................................................................................................................22

9.

...........................................................................................................................23

-

EC-Declaration of Conformity .................................................................................................12

Mounting ...................................................................................................................................16

Accessories

Technical data

4.1
4.2 Mounting guidelines ...........................................................................................................17

5.1 Interfaces ...........................................................................................................................18
5.2 Synchronization .................................................................................................................18

6.1 Operation with transponders ..............................................................................................19
6.2

Dimensions ........................................................................................................................16

Manual address allocation via reader keypad, stand alone mode......................................19

Keypad lighting

7.

Stand alone programming mode .............................................................................................20

7.1 Activate programming mode ..............................................................................................20
7.2 Clear address.....................................................................................................................20
7.3 Load standard values.........................................................................................................20
7.4 Adjustment mode - range...................................................................................................20
7.5

...................................................................................................................22

7.6 Transponder detection .......................................................................................................22
7.7 Exit programming mode .....................................................................................................22

Содержание 026421

Страница 1: ...ten d rfen nur mit einem temperaturgeregelten vom Netz galvanisch getrennten L tkolben vorgenommen werden VDE Sicherheitsvorschriften sowie die Vorschriften des rtlichen EVU sind zu beachten Die Ger t...

Страница 2: ...rtragungsreichweite kann in bestimmten Grenzen eingestellt werden Synchronisation von bis zu 4 dicht nebeneinander montierten Lesern m glich Geringe Stromaufnahme im Mittel 11 mA Besonderheiten der Ta...

Страница 3: ...da sich die Befesti gungsl cher in befinden siehe Abbildung auf beiden Seiten horizontaler Position Befestigungsl cher Zum wird unten in der Mitte eine der beigef gten Plomben eingedr ckt Das Geh use...

Страница 4: ...die Lesertastatur im stand alone Betrieb 3 Tasten 1 7 X siehe 7 4 siehe 7 2 8 7 Stand alone Programmiermodus nur die Betriebsspannung Zur Durchf hrung der Programmierung in diesem Modus ist von 12 V D...

Страница 5: ...m Abgleich Signalton Beliebigen im gew nschten Abstand zum Leser halten D beginnt Quittierung kurzer Transponder Die Abgleichmodus Der Transponder kann jetzt entfernt werden Anzeige erlischt F I Abgle...

Страница 6: ...vom Montageuntergrund und den verwendeten Transpondern Die folgenden Angaben beziehen sich auf eine Reichweite bei Verwendung einer ID Karte Nichtmetallischer Montagegrund bis ca 80 mm bei ID Karte St...

Страница 7: ...rk should only be carried out using a temperature controlled soldering bit that is galvanically separated from the power supply Observe the VDE safety instructions as well as the regulations of the lo...

Страница 8: ...extremely stable transmission Automatic identification of different transponder types Semi automatic range adaptation is possible on virtually all mounting surfaces also on metal Transmission range ca...

Страница 9: ...that the fixing holes are horizontal see illustration To press in one of the enclosed seals at the bottom The housing cannot be opened without destroying the seal lock the housing 18 5 Connection diag...

Страница 10: ...the address is saved in the reader An address can also be deleted in the programming mode Stand alone see 7 2 20 I The activated adjustment mode is indicated at the reader by the bottom green LED tha...

Страница 11: ...ment mode If the transponder is moved out of the power field of the the adjustment mode indicator flashes again after a dead time of approx 3 sec and it can be reset if necessary ID card or other tran...

Страница 12: ...ounting surface Approx max 80 mm with ID card Steel mounting surface Approx max 60 mm with ID card Aluminium as mounting surface Approx max 70 mm with ID card Interface RS 485 and Clock Data Housing d...

Отзывы: