38
FIBER_TIGER_manual, 2021-11-29
6.2.
Removing the protective window
6. Cleaning, maintaining and repairing
Target audience and qualification
Operators and experts
Have ready
Cotton gloves
Safety precautions
• Switch off the superordinate machine (power supply), in particular the laser and
moving parts.
• Leave the purge gas on in order to protect the inner protective window.
Procedure
1. Provide a place where the protective window can be deposited without getting dam-
aged.
2. Wear cotton gloves in order to prevent contamination of optics.
3. Turn the protective window bayonet socket counterclockwise.
4. Pull the socket from the scan head.
An O-ring holds the protective window alongside its circumference in the socket.
5. Carefully press the protective window out of the socket.
6. If necessary replace the 2 O-rings in the socket.
7. Clean the protective window, see section 6.3 on page 39, or replace it.
8. Carefully press the protective window back into the socket.
9. Attach the protective window bayonet socket to the scan head and turn it clockwise
until it locks.
Содержание Fiber Tiger