4.2.3

 

CLEAR Button 

The CLEAR button performs the following actions: 
1.

 

If the user is in an editable field, the field will be set to the lowest possible value. 

2.

 

If the user is viewing the Max Wind Speed, the recorded value will be erased. 

3.

 

If the unit is alarming, all delay counters will be cleared.  

4.2.4

 

GO Button  

Press GO from any menu to return to 
operating mode. 
If the unit is already in operating mode, 
press GO to pause the system and disable 
all alarms.  

 

IMPORTANT:

 Whenever the controller is turned on it is in Operating Mode and the alarms are 

active. If the system was in Paused Mode before a power failure, it will restart in Operating Mode 
when power is restored. 

4.3

 

Program Alarm Thresholds 

To begin, navigate to the Wind Alarms menu: 

1.

 

Press GO until the display shows the operating mode screen (see GO Button, above). 

2.

 

Press MENU to bring up one of the three sub-menu displays. 

3.

 

Press UP or DOWN to reach the Wind Alarms sub-menu. 

Wind Alarms(mph)
1: 25      2: 50

Wind Alarms(mph)
1: 25      2: 50

Wind Alarms(mph)
1: 25      2: 50

MENU

MENU

MENU

MENU

 

       Wind Alarms Menu

                       

Program channel #1

 

 

Program channel #2

 

4.

 

Press MENU again. A blinking block cursor will appear on the Channel #1 value. 

 

Press UP or DOWN to change the wind speed threshold. 

5.

 

Press MENU again. The blinking block cursor will move to Channel #2. 

 

Press UP or DOWN to change the value. 

6.

 

Press MENU again to complete programming the Wind Alarms. 

7.

 

Press GO to return to the operating mode screen. 

4.4

 

Program Alarm Delays 

To begin, navigate to the Alarm Delays menu: 

1.

 

Press GO until the display shows the operating mode screen (see GO Button, above). 

2.

 

Press MENU to bring up one of the three sub-menu displays. 

3.

 

Press UP or DOWN to reach the Alarm Delays sub-menu. 
 

 

Wind:  0.0 (mph)
1: 25      2: 50

GO

 System Paused
  GO to resume

Operating Mode

Paused Mode

Alarm Delays (s)
ON: 5     OFF: 5

Содержание 200-WS-21-A

Страница 1: ...DOC 200 WS 21 A UM 20210209 200 WS 21 A User Manual Dual Set Point Wind Alarm Phone 530 823 7185 Email nova novalynx com Website www novalynx com...

Страница 2: ...ions in the case of delicate or sensitive items If packing facilities are not available take the equipment to the nearest Post Office UPS or other freight service and obtain assistance with the packag...

Страница 3: ...2 3 CLEAR Button 7 4 2 4 GO Button 7 4 3 Program Alarm Thresholds 7 4 4 Program Alarm Delays 7 4 5 DIP Switch Settings 8 5 ANEMOMETER INSTALLATION 8 5 1 Anemometer Siting Considerations 8 5 2 Anemomet...

Страница 4: ...ts and the maximum wind speed value are stored in non volatile memory DIP switch settings select the units mph or kph and enable disable the buzzer Programmable Features Alarm Set Point Wind speed thr...

Страница 5: ...connectors supplied Relay specifications Form C SPDT N O and N C Contact rating 3A 24Vdc 115 VAC Alarm ON OFF delay range 0 to 99 seconds Timing accuracy 2 Measurement range 0 to 99 9 Integration int...

Страница 6: ...on Refer to the DIP Switch Settings section of the manual to correct this situation 4 2 Menu Navigation The programming buttons are below the display 4 2 1 MENU Button Press the MENU button One of the...

Страница 7: ...menu 1 Press GO until the display shows the operating mode screen see GO Button above 2 Press MENU to bring up one of the three sub menu displays 3 Press UP or DOWN to reach the Wind Alarms sub menu...

Страница 8: ...per hour MPH Set the switch ON for kilometers per hour KPH 3 The Tu switch sets the temperature units This is not relevant to the wind alarms so it doesn t matter how this switch is set 4 The Si silen...

Страница 9: ...e mounted at the top of a mast the NovaLynx 200 153 Mounting Arm sold separately can be used to mount the sensor to the side The supporting mast or tower should be properly grounded to minimize lightn...

Страница 10: ...sor 1 Tighten the mounting screws if necessary do not strip the threads in the plastic base of the sensor 2 Spin the anemometer cup assembly It should turn freely A drop of light machine oil e g fishi...

Страница 11: ...ns inside the controller box for placing screws It will be necessary to remove the circuit board to access these points After mounting the case to your wall or panel install the small caps that are in...

Страница 12: ...to a good earth ground an electrical box with an earth connection or a metal cold water pipe that actually enters the ground Failure to provide a ground may cause erratic operation and make the syste...

Страница 13: ...ally Be sure you have programmed the Wind Alarm to the settings you desire and the system is operating properly before you connect power to your external devices 8 ALARM FUNCTIONS The Wind Alarm contr...

Страница 14: ...MPER Menu Up Dn Clr Go PROGRAMMING BUTTONS MODE WIND UNITS TEMP UNITS BUZZER WIND MPH DEG F BUZZ TEMP KPH DEG C SILENT ON OFF Wt Wu Tu Si DIP SETTINGS DUAL SET POINT WIND ALARM 200 WS 21A Alarms OFF R...

Отзывы: