The date and time-stamping of data may be switched off. In the SETUP.TXT file:
TIMESTAMP=T
T =
Y
or
N
If T =
Y
, the date and time stamp will be pre-pended on the data sample.
If T =
N
, data will not be date & time stamped
The following table lists the NovaLynx Settings that were loaded to make the logger compatible with the
selected sensor. The RESET Defaults will result if the RESET command line is included in the SETUP.TXT file.
RESET Defaults
NovaLynx Settings
Variance
WAIT
TIME=11:30:00
Time of Programming
DATE=27/07/2021
Date of Programming
STX=2
STX=2
Unchanged
ETX=10
ETX=13
SENTENCE2=N
SENTENCE2=N
Unchanged
STX2=2
STX2=2
Unchanged
ETX2=10
ETX2=10
Unchanged
LOGSTX=N
LOGSTX=N
Unchanged
LOGETX=Y
LOGETX=Y
Unchanged
LOGSTX2=N
LOGSTX2=N
Unchanged
LOGETX2=Y
LOGETX2=Y
Unchanged
SEPARATOR=N
SEPARATOR=N
Unchanged
NEWLINE=N
NEWLINE=N
Unchanged
TIMEOUT=0
TIMEOUT=0
Unchanged
RX2=N
RX2=N
Unchanged
BAUD=9600
BAUD=9600
Unchanged
PARITY=N,8
PARITY=N,8
Unchanged
RATE=0
RATE=0
Unchanged
SINGLEFILE=N
SINGLEFILE=N
Unchanged
FILE=20.CSV
FILE=20.CSV
Unchanged
TIMESTAMP=Y
TIMESTAMP=Y
Unchanged
LOG_ALL=N
LOG_ALL=N
Unchanged
OUTPUT=N
OUTPUT=N
Unchanged
HANDSHAKE=N
HANDSHAKE=N
Unchanged
RESPONSE="Q"
RESPONSE="Q"
Unchanged
RAW=N
RAW=N
Unchanged
SWITCH=N
SWITCH=N
Unchanged
STARTUP=N
STARTUP=N
Unchanged
RX_INV=N
RX_INV=N
Unchanged
PRIFIX=”..”
PREFIX=
TRIGGER=
TRIGGER=
Unchanged