28
If you intend to add another sensor select "A".
If you do not want to add another sensor select "Q".
You will be asked if you are sure that you want to erase memory.
If you have added or deleted a sensor select "Y" if not select "N" and press "Enter".
If you selected A to add the relative humidity sensor then press "Y", then "Enter".
From the sensor types menu select "5", Humidity.
From the humidity sensors menu select "1", 110-WS-16TH-A. Then press "Enter".
From the sensor input channel select "8", A4. Then press "Enter".
The sensor configuration menu appears and it will show:
Sensor type
Model
Input
Calibration
Humidity
110-WS-16-TH-A
A4
Temperature
225-501/WS-16T
A5
If you intend to add another sensor select "A".
If you do not want to add another sensor select "Q".
You will be asked if you are sure that you want to erase memory.
If you have added or deleted a sensor select "Y" if not select "N" and press "Enter".
Barometric Pressure
Connect the barometetric pressure sensor cable to the terminal strip on the data
acquisition module. This sensor has a three conductor cable. The RED wire is
connected to a +12V terminal. The BLACK wire is connected to a GROUND terminal
and the GREEN wire is connected to terminal A2.
INITIALIZATION OF THE BAROMETRIC PRESSURE SENSOR
Press "M" and "Enter" to get the main menu.
From the main menu press "1", Station setup.
From the station set up menu press "6", Add or remove sensors. Then press "Y", then
"Enter".
From the sensor type menu select "6", Pressure. Then press "Enter".
From the pressure sensors menu select "1", 100-WS-16BP. Then press "Enter".
The menu asks: Enter pressure offset or press Q to quit. Press "Q".