INSTALLATION & SET-UP
4.1 SET-UP CLEARANCES & CONDITIONS
When considering the permanent location for your CNC machine the following should be taken
into consideration:
•
The machine should be installed on a flat surface so that the machine does not rock or
slide during operation.
•
This location should be considered the machine’s
permanent location. If you need to
move it, remove it from the stand first.
•
Make sure your stand is level prior to placing the machine on stand. Improper
installation and an unleveled machine can cause both numerical error and loss of
precision in your machining operation.
•
Set up the bed mill stand so you have plenty of working space. Leave at least 3 to 4 feet
of clearance on the operating side of the machine.
A Dimension B Dimension
C Dimension
D Dimension
NM-200 Bed
Mill
83 in/2110
mm
20 in/500
mm
67 in/1700
mm
81 in/1700
mm
Table 4.1 Clearance Dimension
4.2 POWER REQUIREMENTS
Voltage
Amps
Amps
NM-200 Bed Mill
220
15
Single
Table 4.2 Power Requirements
4.3 STAND REQUIREMENTS
You will need a stand that is capable of supporting the weight of your machine plus the
maximum allowable work piece depending on your bed mill. You will also need to add in this
figure additional weight for work holding devices, cutters and coolant. A good rule is to build a
Содержание NM-200 Pro Series
Страница 1: ...Novakon Systems Ltd NM 200 Pro Series OPERATOR S MANUAL...
Страница 19: ...Figure 5 3 NM 200 Back View 24 25 26 27...
Страница 32: ...Diagram 1 Protective Sheet Metal Covers Mill Head Junction Box...
Страница 34: ...Diagram 2 Proximity Switches Diagram Number Part Number Reference Number Description...
Страница 36: ...Diagram Part Number Reference Number Description...
Страница 39: ...Diagram 4 Column...
Страница 41: ...Diagram 5 Table Bed Assembly...
Страница 47: ......