![NovaFlex Z-Flex DVK-HR Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/novaflex/z-flex-dvk-hr/z-flex-dvk-hr_installation-and-maintenance-instructions-manual_1710520020.webp)
20
Installation Procedure
Z-FLEX
STORM COLLAR/SUPPORT
a.
Slide storm collar/support with flared end down, over and down rigid pipe(s)
until it is just above top of roof flashing.
b.
Seal/waterproof between inside diameter of storm collar/support and outside
diameter of rigid pipe with high temperature Mill-Pac Black sealant.
c.
Secure storm collar/support to rigid pipe with bolt and nut.
Secure Storm
Collar/Support to
Rigid Pipe Just
Above Roof
Flashing & Seal
Between Both
with Sealant
Rigid
Pipe
Storm
Collar/
Support
Roof
Flashing
Fig. 14 Storm Collar/Support Installation
WARNING
Risk of Fire! Risk of Explosion! Risk of Asphyxiation!
High wind conditions, nearby big trees, adjoining roof lines, steep pitched roofs may
cause poor draft or down drafting. In these cases increasing the installation height of
termination above highest point of roof may solve drafting problem. Review
appliance manufacturer's instructions to ensure maximum installed lengths (vertical
and horizontal) are not exceeded.