2.Rear panel, inputs, outputs and settings
Rückansicht, Ein- / Ausgänge und Einstellungen
©
G. Speakon output connectors
©
Speakon Lautsprecheranschlüsse
CH1 provides „2-wire“ access at pins 1+/1-
of CH1 at pins 1+/2+.
• BRIDGE MODE:
• STEREO / PARALLEL MODE:
CH2 provides „2-wire“ access at pins 1+/1-
Bridged output is provided at output connector
Buchse CH1 zur Verfügung (Pins 1+/2+).
Verwendung der Pins 1+/1-.
CH1 bietet „Zweileiter“-Zugriff unter
Verwendung der Pins 1+/1-.
CH2 bietet „Zweileiter“-Zugriff unter
• BRIDGE MODE:
Ausgang im Brückenbetrieb steht an der
• STEREO / PARALLEL MODE:
G
H
HX900 | HX1500 | HX2000 | HX4000
8
9
H. RESET circuit breaker
Automatische Sicherheitsabschaltung
If the power amplifier is overloaded (caused by
too low impedance at powered outputs or
continious input signal), the RESET button of
the circuit breaker will upspring immediately
and will power off the device automatically to
protect the amplifier. Once the unit has cooled
down or the reason for error is disconnected
from the unit, the safety switch can be pressed
to set back to normal operation.
Wenn der Verstärker überlastet wird (durch zu
geringe Impedanz an den Ausgängen oder bei
dauerhaft zu hohem Eingangssignal), wird der
Sicherheitsschalter ausgelöst. Dieser schaltet
das Gerät automatisch ab, um den Verstärker
zu schützen. Sobald das Gerät abgekühlt ist
bzw. die Fehlerquelle vom Gerät getrennt wird,
kann dieser Sicherheitsschalter gedrückt
werden, um den normalen Betrieb wieder
zu ermöglichen.
RESET
3.Technical Data
Technische Daten
Rated Power 1 kHz with 0.5% THD
at 4 ohms stereo:
at 8 ohms stereo:
at 8 ohms mono:
Frequency response at 1 Watt:
Total harmonic distortion (THD):
Intermod. dist. 60 Hz & 7 kHz at 4:1 (full to -30 dB):
Slew rate:
Voltage gain:
Damping factor (8 ohms) 10 Hz - 400 Hz:
S/N ratio (< rat. power, 20 Hz to 20 kHz, A-weighted):
Crosstalk (bel. rat. power) at 1 kHz:
Crosstalk (bel. rat. power) at 20 kHz:
Input sensitivity for full rat. power at 8 ohms:
Input impedance (nom.) balanced:
Input impedance (nom.) unbalanced:
Protection:
Ventilation:
Cooling:
Dimensions unit (mm) W x H x D:
Weight (net):
2 x 450 W
2 x 350 W
900 W
20 Hz - 20 kHz, +0/-1 dB
<0.5%, 20 Hz - 20 kHz
=/< 0.35%
>10V/us
31 dB
>200
>100 dB
-75 dB
-58 dB
0.775 V / 1.4 V
20 k ohms
10 k ohms
482 x 88 x 227 mm
12.7 kg
2 x 750 W
2 x 500 W
1.500 W
20 Hz - 20 kHz, +0/-1 dB
<0.5%, 20 Hz - 20 kHz
=/< 0.35%
>10V/us
33 dB
>200
>100 dB
-75 dB
-58 dB
0.775 V / 1.4 V
20 k ohms
10 k ohms
482 x 88 x 227 mm
13.5 kg
2 x 1.000 W
2 x 700 W
2.000 W
20 Hz - 20 kHz, +0/-1 dB
<0.5%, 20 Hz - 20 kHz
=/< 0.35%
>10V/us
34 dB
>200
>100 dB
-75 dB
-58 dB
0.775 V / 1.4 V
20 k ohms
10 k ohms
482 x 88 x 227 mm
14.5 kg
2 x 2.000 W
2 x 1.400 W
4.000 W
20 Hz - 20 kHz, +0/-1 dB
<0.5%, 20 Hz - 20 kHz
=/< 0.35%
>10V/us
37 dB
>200
>100 dB
-75 dB
-58 dB
0.775 V / 1.4 V
20 k ohms
10 k ohms
482 x 88 x 294 mm
20.6 kg
HX 900
HX 1500
HX 2000
HX 4000
Protection against short circuits, no-load, on/off muting, RF interference
Flow-through ventilation from front to back
Internal heat sinks with forced air. Fan cooled, speed regulated, thermal protection
HX AMPLIFIER
TOP VIEW
AIR FLOW
FRONT