![Nova Florida DELFIS Monothermal Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/nova-florida/delfis-monothermal/delfis-monothermal_installation-use-and-maintenance-manual_1710421022.webp)
22
Technical features and dimensions
Description
um
Max. output
Min. output
30% load
Heat loss from the boiler casing
%
3,04
4,24
-
Flue system heat loss with burner on
%
6,86
8,56
-
Flue system mass capacity
g/s
16,72
14,98
-
Flue temp. – air temp.
°C
83
62
-
CO2 value (methane/butane/propane)
%
5.7 / 6.7 / 7.3
3.0 / 3.5 / 3.7
-
Maximum heat output efficiency rating
%
90,1
87,15
88,45
NOx emission class
-
2
Tab. 3 CTN 24 combustion specifications
2.6 ERP and Labelling data
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Rated heat output
P
rated
22
kW
Seasonal space heating energy
efficiency
η
S
76
%
At rated heat output and high-
temperature regime (*)
P
4
22,1
kW
At rated heat output and high-
temperature regime (*)
η
4
81,1
%
At 30 % of rated heat output and low-
temperature regime (**)
P
1
6,5
kW
At 30 % of rated heat output and low-
temperature regime (**)
η
1
79,7
%
At full load
el
max
0,012
kW
Standby heat loss
P
stby
0,150
kW
At part load
el
min
0,011
kW
Ignition burner power consumption
P
ign
0,000
kW
In standby mode
P
SB
0,001
kW
Annual energy consumption
Q
HE
84
GJ
Emissions of nitrogen oxides
NO
x
149
mg/kWh
Sound power level, indoors
L
WA
52
dbA
Daily electricity consumption
Q
elec
0,107
kWh
Daily fuel consumption
Q
fuel
24,650
kWh
Annual electricity consumption
AEC
23
kWh
Annual fuel consumption
AFC
18
GJ
C
B
Seasonal space heating energy efficiency class
Water heating energy efficiency class
For combination heaters:
Model(s): DELFIS CTN 24
Condensing boiler: no
Low-temperature (**) boiler: no
B1 boiler: yes
Cogeneration space heater: no
If yes, equipped with a supplementary heater: -
Combination heater: yes
For boiler space heaters and boiler combination heaters:
Useful heat output
For boiler space heaters and boiler combination heaters:
Useful efficiency
Auxiliary electricity consumption
Other items
%
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet).
77
Contact details: FONDITAL S.p.A. - Via Cerreto, 40 I-25079 VOBARNO (Brescia) Italia - Italy
Declared load profile
XL
Water heating energy efficiency
η
wh
Tab. 4 ERP and Labelling data
Содержание DELFIS Monothermal
Страница 46: ...46...