background image

24

Simplex 4010 NION Installation/Operation Manual  Version 2   Document 51998  Rev. A1  03/26/03

NOTIFIER

®

 warrants its products to be free from defects in materials and workmanship

for eighteen (18) months from the date of manufacture, under normal use and service.
Products are date stamped at time of manufacture.  The sole and exclusive obligation
of NOTIFIER

®

 is to repair or replace, at its option, free of charge for parts and labor,

any part which is defective in materials or workmanship under normal use and service.
For products not under NOTIFIER

®

 manufacturing date-stamp control, the warranty

is eighteen (18) months from date of original purchase by NOTIFIER

®

's distributor

unless the installation instructions or catalog sets forth a shorter period, in which case
the shorter period shall apply.  This warranty is void if the product is altered, repaired
or serviced by anyone other than NOTIFIER

®

 or its authorized distributors or if there

is a failure to maintain the products and systems in which they operate in a proper
and workable manner.  In case of defect, secure a Return Material Authorization form
from our customer service department.  Return product, transportation prepaid, to
NOTIFIER

®

, 12 Clintonville Road, Northford, Connecticut  06472-1653.

This writing constitutes the only warranty made by NOTIFIER

®

 with respect to its

products.  NOTIFIER

®

 does not represent that its products will prevent any loss by

fire or otherwise, or that its products will in all cases provide the protection for
which they are installed or intended.  Buyer acknowledges that NOTIFIER

®

 is not

an insurer and assumes no risk for loss or damages or the cost of any inconvenience,
transportation, damage, misuse, abuse, accident or similar incident.

NOTIFIER

®

 GIVES NO WARRANTY, EXPRESSED OR IMPLIED, OF

MERCHANTABILITY, FITNESS FOR ANY PARTICULAR PURPOSE, OR
OTHERWISE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE
HEREOF.  UNDER NO CIRCUMSTANCES SHALL NOTIFIER

®

 BE LIABLE FOR

ANY LOSS OF OR DAMAGE TO PROPERTY, DIRECT, INCIDENTAL OR
CONSEQUENTIAL, ARISING OUT OF THE USE OF, OR INABILITY TO USE
NOTIFIER

®

 PRODUCTS.  FURTHERMORE, NOTIFIER

®

 SHALL NOT BE LIABLE

FOR ANY PERSONAL INJURY OR DEATH WHICH MAY ARISE IN THE COURSE
OF, OR AS A RESULT OF, PERSONAL, COMMERCIAL OR INDUSTRIAL USE
OF ITS PRODUCTS.

This warranty replaces all previous warranties and is the only warranty made by
NOTIFIER

®

.  No increase or alteration, written or verbal, of the obligation of this

warranty is authorized.

"NOTIFIER" is a registered trademark.

Limited Warranty

Technical Manuals Online! - http://www.tech-man.com

firealarmresources.com

Содержание UniNet 2000 Simplex 4010 NION

Страница 1: ...x 4010 NION A1 51998 A1 ECN 02 298 Document 51998 03 26 03 Rev UniNet 2000 Simplex 4010 NION Installation and Operation Manual Version 2 Technical Manuals Online http www tech man com firealarmresourc...

Страница 2: ...2 Simplex 4010 NION Installation Operation Manual Version 2 Document 51998 Rev A1 03 26 03 This page intentionally left blank Technical Manuals Online http www tech man com firealarmresources com...

Страница 3: ...ns caused by escaping gas improper storage of flammable mate rials etc Heat detectors do not sense particles of combustion and alarm only when heat on their sensors increases at a predetermined rate o...

Страница 4: ...efore making modifica tions verify that they will not interfere with battery transformer and printed circuit board location Do not tighten screw terminals more than 9 in lbs Over tightening may damage...

Страница 5: ...4010 NION Architecture 15 Figure 2 2 Simplex 4010 NION to Simplex 4010 9811 Serial Connections 16 2 2 Simplex 4010 NION Enclosure and Mounting 17 Figure 2 3 Simplex 4010 NION Power Connection 17 Figu...

Страница 6: ...6 Simplex 4010 NION Installation Operation Manual Version 2 Document 51998 Rev A1 03 26 03 Technical Manuals Online http www tech man com firealarmresources com...

Страница 7: ...originating from a Simplex 4010 panel UniNet consists of graphical workstations monitoring and controlling local or remote twisted pair or fiber optic networks Remote network monitoring is achieved t...

Страница 8: ...8 Simplex 4010 NION Installation Operation Manual Version 2 Document 51998 Rev A1 03 26 03 This page intentionally left blank Technical Manuals Online http www tech man com firealarmresources com...

Страница 9: ...technologies The Simplex 4010 NION provides transparent or interpreted communications between the workstation and control panel The NION connects a LonWorks FT 10 or fiber optic network to a fire ala...

Страница 10: ...SW2 Network SW2 Network SW2 Network SW2 Network SW2 Network Binding Button Binding Button Binding Button Binding Button Binding Button SW1 Reset SW1 Reset SW1 Reset SW1 Reset SW1 Reset Button Button B...

Страница 11: ...ween monitored equipment and the network Connections One twisted pair of wires or dedicated fiber optic cable is used for data transmission in the UniNet network The wire must be Twisted pair cable UL...

Страница 12: ...transformer isolated making all network communication immune to ground fault conditions Therefore no ground fault supervision of the Echelon network is required or provided FTXC PCA and FTXC PCB Netwo...

Страница 13: ...when an error occurs This suppresses noise propagation throughout the network Figure 1 5 Sample Style 7 Networks For more information about Style 7 network configuration refer to the Local Area Server...

Страница 14: ...r allow runs of up to 12db of attenuation between each node with up to 64 nodes per segment DFXC DFXC DFXC DFXC DFXC Dual Fiber Optic Transceiver Figure 1 6 FOXC PCA and DFXC PCA Fiber Optic Network T...

Страница 15: ...ON NION NION NION NION NION EchelonT EchelonT EchelonT EchelonT EchelonTo Other Nodes o Other Nodes o Other Nodes o Other Nodes o Other Nodes Ethernet T Ethernet T Ethernet T Ethernet T Ethernet To Ot...

Страница 16: ...rial Connections The Simplex 4010 NION requires that a Simplex model 4010 9811 dual EIA 232 card be installed in the Simplex 4010 FACP The NION communicates to the 4010 FACP through serial port P6 onb...

Страница 17: ...er 3 Mount the enclosure to the wall Refer to the enclosure mounting hole layout below Figure 2 4 NISCAB 1 Enclosure Mounting Hole Layout Power Requirements and Connection The Simplex 4010 NION requir...

Страница 18: ...ting Studs w Standoffs Mounting Studs w Standoffs Mounting Studs w Standoffs Mounting Studs w Standoffs Figure 2 5 Installing the NION in a NISCAB 1 Mounting NION boards within the enclosure When inst...

Страница 19: ...CHANGE button on the form This will cause a dialogue box to be displayed with the names of all available configuration files Select SX4010 cfg and then click the OPEN button Finally click DONE to end...

Страница 20: ...Simplex 4010 Explorer The Simplex 4010 NION is easily configured to communicate with a Simplex 4010 FACP via the Simplex 4010 Explorer Only an operator with administrator privileges can access configu...

Страница 21: ...ces or labels are added or changed a Panel Learn must be performed again Figure 3 4 Duplicate Device Labels The Simplex 4010 devices must not have any duplicate device labels If duplicate device label...

Страница 22: ...ppress Psuedo Points box in the data display See figure 3 6 UL Functionality This option will be displayed only if the current operator is logged in as an administrator This option must always be chec...

Страница 23: ...M M M M M Mounting 17 N N N N N NFN Explorer Overview 19 NION NPB 9 NISCAB 1 17 P P P P P Power Requirements 11 R R R R R Required Equipment 9 Index S S S S S Serial Communication Settings 16 Serial C...

Страница 24: ...o NOTIFIER 12 Clintonville Road Northford Connecticut 06472 1653 This writing constitutes the only warranty made by NOTIFIER with respect to its products NOTIFIER does not represent that its products...

Отзывы: