background image

NCM Installation  PN 51533:A1  03/27/03

1  Product Overview

The Network Communications Module (NCM) provides a means for connecting specific Notifier fire 
alarm control products to 

NOTI•FIRE•NET™

.  There are two types of NCMs available: NCM-W for 

connecting nodes with twisted-pair wire, and NCM-F for connecting nodes with fiber-optic cable.  

1.1  The Network Communications Module for Wire (NCM-W)

• Supports twisted-pair wire medium.
• NFPA Style 4 (Class B) operation or NFPA Style 7 (Class 

A) operation.

• Two programmable data thresholds.
• Transformer coupling provides electrical isolation 

between nodes.

• Pluggable terminal wiring with strain relief.
• Pluggable service connector (feeds signal directly 

through) in the event that power must be removed from a 
node.

• 312.5 Kbaud transmission rate.
• Data is regenerated at each node.
• Two network ports to allow simultaneous connection to 

fire alarm control panel and to programming computer

• Enables software and database upload/download over 

NOTI•FIRE•NET™

.

• Refer to the 

NOTI•FIRE•NET™

 Manual (Network 

Version 4.0 and Higher)

 for wiring length and threshold 

information.

1.2  The Network Communications Module for Fiber (NCM-F)

• Supports fiber-optic medium.
• NFPA Style 4 (Class B) or Style 7 (Class A) operation.
• Data is immune to all environmental noise.
• Optical isolation prevents ground loops.

NOTI•FIRE•NET™

 fiber optic medium.

• Fiber type: 

• 62.5/125 micrometers (multimode, 8 dB limit)
• 50/125 micrometers (multimode, 4.2 dB limit)

• Wavelength (1): 820 nanometers.  (Use standard 850 nm 

fiber.)

• Connectors: ST® Style (ST® is a registered trademark of 

AT&T).

• 312.5 Kbaud transmission rate.
• Data is regenerated at each node.
• Two network ports to allow simultaneous connection to 

fire alarm control panel and to programming computer.

• Enables software and database upload/download over 

NOTI•FIRE•NET™

.

RECON PULSE1

LED6

LED7

LED10 1

LED10 0

LED4

LED2

LED3

LED5

LED1

LED8

STATA STATB

RCDA

RCDB

A HI

B   HI

EF B TER M B

S

W

101

SW

1

02

S

W

103

O

N

  

    

  O

F

F

EF A   TERM  A

SW

1

00

O

N

  

    

  O

F

F

NUP

1

NUP

2

J3

J2

LCM

A

TERM

A

SW

1

ON

S W 2

OFF

LC

M

  A

LC

M

  B

RE SET POW ER

Ground Fault 
Detection 
Switches
and 
Network 
End-of-Line 
Termination 
Resistor 
Switches

Figure 1  NCM-W

NCM-w

.c

dr

Diagnostic 
LEDs

Network 
Connection 
Ports 
(NUP)

Not used

Channel 
A & B 
Connections

NC

M

-f.cd

r

Figure 2  NCM-F

Diagnostic 
LEDs

Network 
Connection 
Ports 
(NUP)

Channel 
A & B 
Connections

Not used

12 Clintonville Road
Northford, CT 06472-1653 USA
www.notifier.com

NCM Installation Document

Network Communications Module NCM-W, NCM-F

PN 51533:A1

03/27/03

ECN 03-171