![Nothern Lights M38CR2 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/nothern-lights/m38cr2/m38cr2_operators-manual_1709815025.webp)
OM944T 2/11
25
GENERATOR END
The maintenance and operation recommendations for
the generator end are in a separate Owner's Manual.
If you do not have one of these manuals, contact your
local dealer.
ELECTRICAL SYSTEM - GENERAL
1. Never switch the battery switch off or break the
circuit between the alternator and the batteries while
the engine is running. Alternator damage can result.
2. Do not reverse the polarity of the battery cables
when installing the battery.
BOOSTER BATTERIES
CAUTION: Battery gas can explode. Keep all
fl ames and sparks away from batteries.
1. Before changing or using booster batteries, check
the battery electrolyte level. Add distilled water if
necessary.
2. Booster and main batteries must have the same
voltage
rating.
3. First, connect the positive (+) terminal of the booster
battery to the positive (+) terminal of the main
battery. Then, connect the negative (–) terminal of
the booster battery to ground on the engine block
(
Figure 10
).
4. Remove the booster battery after starting the engine.
5. Sealed Batteries:
See the manufacturer's charging and booster
instructions.
Servicing
Figure 12: Booster Battery Connections