SERVICE PRO

®

 CONTROL CENTER

Prewired controls are supplied in a sealed NEMA rated 

enclosure for your safety and the protection of components 

and wiring.  The controls should be located so the alarm 

light  can  be  seen  and  the  audible  alarm  heard,  while 

minimizing exposure to harsh weather or conditions that 

might prevent routine access.  If an issue with the aerator is 

detected, the red alarm light will flash and the control center 

will attempt to restart the aerator every five minutes for 

two hours.  For an open motor or under current condition, 

the alarm light will display two short flashes followed by a 

pause.  For an over current condition, the alarm light will 

flash evenly.  If the aerator does not restart after two hours, 

the audible alarm will sound.  To silence the audible alarm 

and attempt to restart the aerator, push the reset button.  If 

the alarm condition is not resolved, the audible alarm will 

be silenced for 48 hours, but the alarm light will continue 

to flash.  In this case, contact your service provider.  Model 

960 systems are supplied with a time clock adjustable in 

five minute increments up to continuous run.  This clock is 

factory preset to run 30 minutes per hour and should only be 

adjusted by an authorized Singulair service provider.  Model 

TNT systems are supplied with a non-adjustable time clock.

SERVICE PRO

® 

MONITORING CENTER

An optional Service Pro MCD control center is available 

for use with the Singulair system.  Designed to connect 

to a standard telephone line or internet connection, this 

control  center  provides  MONITORING,  COMPLIANCE 

and DIAGNOSTIC functions complete with telemetry for 

communication  with  the  Service  Pro  monitoring  center. 

 

Once your Service Pro MCD control center is connected to 

a telephone line or internet connection, commissioned, and 

covered by a remote monitoring agreement, your service 

provider will be immediately notified of any alarm condition.  

The Service Pro monitoring center will automatically log 

the time and date of alarm conditions, as well as service 

performed, and store them in your system history record 

for viewing at 

www.servicepromcd.com

.   

 

NOTE: 

The control center regularly communicates with the 

Service Pro monitoring center using your telephone line or 

an internet connection.  If the control center is using the 

telephone line when you attempt to place a call, a high 

pitched digital communication signal will be heard.  Hang 

up all telephones sharing the line and wait a few seconds.  

This will automatically disconnect the control center and 

make the line available for use.

BIO-STATIC

®

 SLUDGE RETURN

Each Bio-Static sludge return is installed in the aeration/

clarification  chamber  wall.   Aeration  chamber  hydraulic 

currents enter the sludge return(s) and transfer solids from 

the  clarification  chamber  back  to  the  aeration  chamber 

for  additional  treatment.   The  Bio-Static  sludge  return  

accomplishes  resuspension  and  return  of  settled  solids 

without disturbing the contents of the clarification chamber.  

BIO-KINETIC

®

 SYSTEM

Bio-Kinetic  systems  provide  non-mechanical  flow 

equalization through all plant processes.  The Bio-Kinetic 

system contains 3 separate filtration zones, 8 independent 

settling  zones,  optional  chlorination  and  dechlorination 

tablet feed systems and serves as its own chlorine contact 

chamber.  When used with Blue Crystal disinfecting tablets, 

the performance of the Bio-Kinetic system as a disinfection 

device is certified to NSF/ANSI Standard 46, Section 11.  

All components are manufactured from plastic or rubber.  

Your service provider has the necessary training, tools and 

equipment for removal and cleaning.  If your Bio-Kinetic 

system is in need of service, contact your service provider.  

During each semi-annual service inspection, your service 

provider will remove and clean the Bio-Kinetic system or 

replace it with a unit from their service stock.