SERVICE PRO
®
CONTROL CENTER
Prewired controls are supplied in a sealed NEMA rated
enclosure for your safety and the protection of components
and wiring. The controls should be located so the alarm
light can be seen and the audible alarm heard, while
minimizing exposure to harsh weather or conditions that
might prevent routine access. If an issue with the aerator is
detected, the red alarm light will flash and the control center
will attempt to restart the aerator every five minutes for
two hours. For an open motor or under current condition,
the alarm light will display two short flashes followed by a
pause. For an over current condition, the alarm light will
flash evenly. If the aerator does not restart after two hours,
the audible alarm will sound. To silence the audible alarm
and attempt to restart the aerator, push the reset button. If
the alarm condition is not resolved, the audible alarm will
be silenced for 48 hours, but the alarm light will continue
to flash. In this case, contact your service provider. Model
960 systems are supplied with a time clock adjustable in
five minute increments up to continuous run. This clock is
factory preset to run 30 minutes per hour and should only be
adjusted by an authorized Singulair service provider. Model
TNT systems are supplied with a non-adjustable time clock.
SERVICE PRO
®
MONITORING CENTER
An optional Service Pro MCD control center is available
for use with the Singulair system. Designed to connect
to a standard telephone line or internet connection, this
control center provides MONITORING, COMPLIANCE
and DIAGNOSTIC functions complete with telemetry for
communication with the Service Pro monitoring center.
Once your Service Pro MCD control center is connected to
a telephone line or internet connection, commissioned, and
covered by a remote monitoring agreement, your service
provider will be immediately notified of any alarm condition.
The Service Pro monitoring center will automatically log
the time and date of alarm conditions, as well as service
performed, and store them in your system history record
for viewing at
www.servicepromcd.com
.
NOTE:
The control center regularly communicates with the
Service Pro monitoring center using your telephone line or
an internet connection. If the control center is using the
telephone line when you attempt to place a call, a high
pitched digital communication signal will be heard. Hang
up all telephones sharing the line and wait a few seconds.
This will automatically disconnect the control center and
make the line available for use.
BIO-STATIC
®
SLUDGE RETURN
Each Bio-Static sludge return is installed in the aeration/
clarification chamber wall. Aeration chamber hydraulic
currents enter the sludge return(s) and transfer solids from
the clarification chamber back to the aeration chamber
for additional treatment. The Bio-Static sludge return
accomplishes resuspension and return of settled solids
without disturbing the contents of the clarification chamber.
BIO-KINETIC
®
SYSTEM
Bio-Kinetic systems provide non-mechanical flow
equalization through all plant processes. The Bio-Kinetic
system contains 3 separate filtration zones, 8 independent
settling zones, optional chlorination and dechlorination
tablet feed systems and serves as its own chlorine contact
chamber. When used with Blue Crystal disinfecting tablets,
the performance of the Bio-Kinetic system as a disinfection
device is certified to NSF/ANSI Standard 46, Section 11.
All components are manufactured from plastic or rubber.
Your service provider has the necessary training, tools and
equipment for removal and cleaning. If your Bio-Kinetic
system is in need of service, contact your service provider.
During each semi-annual service inspection, your service
provider will remove and clean the Bio-Kinetic system or
replace it with a unit from their service stock.