Never adjust this protection under 40Watt. The amplifier will destroy.
Protection amplifier’s excessive temperature of the
transmitter.
It has adjust from the factory to 60 Celsius degrees. You have the ability to
adjust this protection to 1-100 Celsius degrees.
Never outdistance 70 degrees. If the transmitter exceedingly heated you
must read carefully this specific manual to the first pages to make sure that you
didn’t do any mistake during the transmitter’s installation.
Frequency Calibration Menu
We took the idea from the transceivers and we wanted to solve a problem that
the DDS present as time goes by, a little sliding that can be happen from the
oscillators or from the temperature’s change or even with the corruption of some
materials as time goes by.
Although to slide an exciter a little to AM is not such a big problem, we wanted to
add it and to give to the user the ability to solve this problem.
In this menu we can shift the BFO with a step 1Hz total,
+50Hz up or -50Hz down. This is setting to 0Hz from the factory.
PROTECTIONS AND ACTIVATION.
Every time you activate a protection, you
will see it at the transmitter’s screen. The transmitter stops to send out. The
transmitter stops to send out, the red led switch on which is the last at the line
STATUS at the left side of the transmitter and while the protection shown at the
screen.
When some of the protections activate at the screen, except from the kind
of the protection, showns also the effort but also the seconds of the
countdown.