background image

Northstar

 Explorer D210 

Installation and Operation Manual

7

Master/Slave Selection

To select the master/slave mode of operation:

1.  Apply power while holding down 

.

Hold down during power up

2.  When the unit is on. The display will indicate 

the current display unit:

example

3. Continue 

to 

hold   until the display 

indicates the current master/slave selection.

  

 

 

  Master 

Slave

4. Use   and 

 to change the selection.

5.  To exit this mode, press and hold both 

 and 

 simultaneously.  Alternatively, if no keys 

are pressed for a period of 5 seconds normal 
depth display will resume.

  

Press simultaneously

Note:

 

If the data link is inadvertently broken then 

the display will alternate between -- and -SL.

Linked or Separate Selection

By default a dual station pair of Explorer D210 
instruments automatically keep the following 
settings the same in both instruments:

 Alarms 

On/Off

 

Alarm Values (Deep and Shallow)

 

Keel Offset (see note)

 

Units of measure (see note)

Example: Switching an alarm off on the slave 
instrument will also switch the alarm off 
on the master instrument. The reverse also 
applies, alarms changed on the master will be 
automatically changed in the slave instrument.

Note:

 

The keel offset and units of measure should 

only be changed on the Master instrument.

If independent settings are required the link 
feature can be disabled.

To enable or disable the linked mode:

1.  Apply power while holding down 

.

Hold down during power up

2.  When the unit is on. The display will first 

indicate the current display unit:

Example

3.  Continue to hold 

. The display will indicate 

the current master/slave selection.

Slave

4.  Continue to hold 

 until the display 

indicates the current linked/separate 
selection.

  

Linked

         

Separate

5. Use   and 

 to change the selection.

6.  To exit this mode, press and hold both 

 and 

 simultaneously.  Alternatively, if no keys 

are pressed for a period of 5 seconds normal 
depth display will commence.

  

Press simultaneously

Note:

 

This setup procedure applies to the master 

device and all slave devices. For separate operation 
all devices, including the master, must be set to 
Separate mode. Also, for linked operation all devices, 
including the master, must be set to Linked mode.

OFF

ON

OFF

ON

OFF

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

ON

OFF

ON

OFF

ON

OFF

ON

OFF

OFF

ON

OFF

ON

OFF

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

ON

OFF

ON

OFF

ON

OFF

ON

OFF

OFF

ON

OFF

ON

OFF

ON

OFF

ON

Содержание EXPLORER D210

Страница 1: ...www northstarnav com Explorer D210 Installation and Operation Manual ...

Страница 2: ... messages that follow this symbol to avoid possible injury or death WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a potentially hazardous situation which if not avoided could result in minor or moderate injury CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avo...

Страница 3: ...Deep Alarm 4 2InstrumentSetup 5 Keel Surface Offset 5 Transducer Setting 5 Units of Measure 5 3DualStationOperation 6 Master Slave Selection 7 Linked or Separate Selection 7 4Maintenance 8 5Installation 8 Instrument Installation 8 6Wiring 9 AppendixA Specifications 10 AppendixB Troubleshooting 11 AppendixC Howtocontactus 12 ...

Страница 4: ... turn the alarms off press OFF The arrow in the lower right corner will extinguish Note The arrow will flash if alarms are turned ON but the shallow alarm is individually set to OFF See next section ShallowAlarm To set the shallow alarm 1 Press for three seconds The display will show 2 After a few seconds the display will indicate the current Shallow Alarm depth setting 3 Use and to change the val...

Страница 5: ...ed on the left hand side of the display 6 To display depth below the keel enter the vertical distance between the bottom of the keel and the depth transducer as a negative value 7 To display depth below surface enter the vertical distance from the waterline to the depth transducer as a positive number no negative sign 8 To exit this mode press and hold both and simultaneously Alternatively if no k...

Страница 6: ... and to change the value 4 To exit this mode press and hold both and simultaneously Alternatively if no keys are pressed for a period of 5 seconds normal depth display will resume Press simultaneously The display will now indicate the current water depth in the selected display unit Multiple Explorer 210 instruments can be installed on a single vessel These instruments can be connected together an...

Страница 7: ... changed on the master will be automatically changed in the slave instrument Note The keel offset and units of measure should only be changed on the Master instrument If independent settings are required the link feature can be disabled To enable or disable the linked mode 1 Apply power while holding down Hold down during power up 2 When the unit is on The display will first indicate the current d...

Страница 8: ...unting nut until the bracket is secure 6 Connect the power cord at the back of the instrument to a 12 V power supply which is active whenever the ignition switch is on The red lead should be connected to the positive terminal of the power supply via a 1 amp fuse or a 1 amp circuit breaker The black lead should be connected to the negative terminal Your depth sounder is designed for years of troubl...

Страница 9: ...l to complete circuit If unused then tape to avoid shorting BrownDatainput output Your Explorer D210 can be used as a repeater for another DPT or DBT NEMA depth sounder If unused then tape to avoid shorting Bracket Buzzer RCA Jack Connector 600 mm 24 inch Power Cord Black Red Orange Brown 6 Wiring If unsure about wiring contact your nearest Northstar dealer ...

Страница 10: ...Operating Voltage 9 5 V DC to 16 5 V DC Operating Temperature 0 C to 50 C 32 F to 122 F Current Drain 150 mA max including internal buzzer Data Input Output Single wire data output Input Dual station mode outputs NMEA sentences Dual station accepts NMEA sentences In the linked mode a dual station pair also transfer function settings eg Alarm on off NMEA Output DPT NMEA Input DPT and DBT External B...

Страница 11: ... free of corrosion Erraticreadingswhilemoored 1 Check transducer for growth or multiple coats of paint Appendix B Troubleshooting Erraticreadingswhilemoving 1 Cavitation air under the face of the transducer Review installation and reinstall if necessary Erraticreadingsonlywhileengineisrunning 1 Re route power and transducer cables away from engine ignition wires and battery cables 2 Add feed throu...

Страница 12: ...ROPE Unit 2 Ocean Quay Belvidere Rd Southampton SO14 5QY ENGLAND Ph 44 2380 339922 Fax 44 2380 330345 northstaruk northstarnav com AUSTRALIA PO Box 479 Gladesville NSW 2111 AUSTRALIA Ph 61 2 9879 9060 Fax 61 2 9879 9009 northstaraus northstarnav com NEW ZEALAND PO Box 68 155 Newton Auckland Auckland NEW ZEALAND Ph 64 9 481 0500 Fax 64 9 481 0590 northstarnz northstarnav com ...