5

Reference 19 -  120 Volt-30  Amp  Locking

Receptacle.  

The control panel is equipped  with one

NEMA L5-30R receptacle.  This receptacle accepts
only  NEMA L5-30P plugs.

Reference 20 -120/240 Volt-30  Amp  Locking

Receptacle.  

The control panel is equipped  with one

NEMA L14-30R  receptacle.  This  receptacle accepts
only NEMA L14-30P plugs. This receptacle is popular
for connection to a transfer switch for home standby
power. See item #16412 in the NORTHERN catalog.

Reference 21 - Hour Meter.  

The hour meter

allows for monitoring of engine  maintenance
schedules.

Reference 22 - Voltmeter.  

The voltmeter allows

for monitoring of the generator.  The needle  should be
in the  green area  for all load  conditions.

GENERATOR FEATURES NOT SHOWN

Fuel Shut Off Valve.  

The fuel tank is equipped

with a fuel shut off valve. Always  turn  the  fuel  valve  to
the off position when the generator is not in use.  The
valve is located underneath the fuel tank.

             INTRODUCTION

Before starting your generator,  thoroughly  study

the instructions and cautions in this manual to assure
you are fully acquainted with the operation of all
components of this generator. Proper preparation,
operation and maintenance will  result in  operator
safety,  best  performance and  long life of the  generator.
For detailed engine operation and maintenance always
refer to the Hatz engine owner’s manual furnished with
the generator.

NorthStar is constantly improving its  products.

The specifications outlined herein are subject  to
change without prior notice  or  obligation.   The
purchaser and/or user assumes  liability  of  any
modification and/or alterations on this equipment from
original design and manufacture.

Before using, the user shall determine the

suitability of this product  for its  intended use  and
assumes liability therein.

   ANSI SAFETY DEFINITIONS

DANGER

 indicates an imminently  hazardous

situation which, if not avoided, will result in death or
serious injury.  This signal word is to be limited to the
most extreme situations.

WARNING

 indicates a  potentially hazardous

situation which, if not avoided, could  result in a
death or

 

serious injury.

CAUTION

 indicates a  potentially hazardous

situation,  which if not avoided,  may  result in minor  or

moderate injury.  It may also be used to alert  against
unsafe practices.

RULES FOR SAFE OPERATIONS

Safety precautions are essential when operating

this generator. Respectful and cautious  operation  will
considerably lessen the possibilities of a personal
injury.  This manual will warn of specific personal injury
potential, and these will be designated by the symbol:

                      

 

WARNING

 This generator is equipped

with a grounding screw located on the rear of the
generator.  Always complete the grounding path from
the generator to a copper pipe/rod  that  is  driven  into
moist earth, to prevent electrical shock.

ALWAYS

 use  electrical  cords  that are in good

condition.  Worn, bare, frayed or otherwise  damaged
cords can cause electric shock.

NEVER

 operate the generator, or handle  any

electrical equipment while standing in water, while
barefoot, while hands are wet or while in the rain or
snow.  Electric shock may result.

ALWAYS

 use a ground  fault  circuit interrupter

(GFCI) in damp or highly electrical conductive areas
and on construction job-sites to prevent electric shock.

ALWAYS 

disconnect the battery before  working

on the engine or generator.  Disconnect the  negative
cable first then the positive cable.  The key should be
in the OFF position  when  disconnecting or  connecting
battery cables.

ALWAYS 

provide adequate ventilation. Do not

operate generator  in any enclosed or  narrow  space.
Engines consume oxygen and give off deadly  carbon
monoxide poisonous gas.  Improper ventilation  will
cause damage to generator and possible injury to
people.

NEVER 

touch hot muffler, hot exhaust manifold or

engine cooling fins.

ALWAYS

 

remove all oil  or  fuel deposits  and

accumulated dirt from generator and immediate area.
Keep generator and engine clean.

NEVER

 operate the generator  under  the  following

conditions:

A. Excessive change in engine speed, slow or
      fast.
B. Overheating of load connecting devices.
C. Sparking or arcs from generator.
D.  Loss of electrical output.
E. Damaged receptacles.

Содержание 6500 DPG

Страница 1: ...P e r f o r m a n c e MODEL 6500 DPG ITEM 165961 Diesel Portable Generator M165961B OWNER S MANUAL Call Customer Service at 1 800 270 0810 Hours Monday Friday 7 00 AM to 5 00 PM CST Saturday 7 30 AM to 11 30 AM CST ...

Страница 2: ...RTANT Make certain the operator Reads and understands the manuals pertaining to this machine Is instructed in safe and proper operation of this machine NOTICE K BAR Industries Incorporated reserves the right to make improvements in design and or changes in specifications at any time without incurring any obligation to install them on units previously sold TABLE OF CONTENTS Thank you 1 Specificatio...

Страница 3: ...l Capacity 1 76 US quarts 1 65 L Starting Method Electric Recoil 120V Receptacle 20 Amp A Duplex GFCI NEMA 5 20R 30 Amp A Locking NEMA L5 30R 120 240V Receptacle 30 Amp A Locking NEMA L14 30R Circuit Breakers 30 Amp A Magnetic Qty 1 20 Amp A Thermal type Qty 2 Grounding Screw Receives 10 Ga Fork Terminal Battery 12 Volt battery with an ampere hour rating of at least 36 AH Dimensions Length 34 00 8...

Страница 4: ...r 9 Air Cleaner Housing 2 Grounding Screw 10 Recoil Handle 3 Control Panel 11 Muffler 4 Isolation Mounts 12 Battery Box 5 Oil Drain Plug 13 Warning Decals 6 Oil Filter Access Cover 14 6 5 Gallon Fuel Tank 7 Oil Fill and Dip Stick 15 Fuel Cap with Gauge 8 Operation Instructions Figure 2 Ref 10 15 2276 ...

Страница 5: ...l accept a standard lawn tractor size battery Group U1 7 The engine requires a 12 volt battery with a minimum rating of 36 Ah Amp hour When installing the battery always connect the red colored positive or cable first When disconnecting the battery always remove the black colored negative or cable first WARNING Sulfuric acid is a corrosive poison Avoid contact with skin eyes or clothing Always wea...

Страница 6: ... WARNING indicates a potentially hazardous situation which if not avoided could result in a death or serious injury CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices RULES FOR SAFE OPERATIONS Safety precautions are essential when operating this generator Respectful and cautious opera...

Страница 7: ...ion is eliminated and a dead short can result Always compare the generator nameplate data with that of the equipment to be used to ensure that watts volts amperage and frequency requirements are suitable for operating equipment The wattage listed on the equipment nameplate is its rated output However some equipment may require three to ten times more wattage than its rating on the nameplate as the...

Страница 8: ...ing an extension cord with a small wire size Use this chart to estimate the total load on your generator For Determining Generator Load Requirements Device Running Watts Air Conditioner 12 000 Btu 1700 a Battery Charger 20 Amp 500 Belt Sander 3 1000 Chain Saw 1200 Circular Saw 6 1 2 900 Coffee Maker 1000 Compressor 1 HP 2000 a Compressor 3 4 HP 1800 a Compressor 1 2 HP 1400 a Curling Iron 700 Dish...

Страница 9: ... continued and proper operation of the generator The voltage can be checked with a portable voltmeter Frequency can be checked by using a electric clock with a sweep second hand Timed against a wristwatch or stopwatch The clock should be correct within 2 seconds per minute A qualified technician should accomplish engine speed adjustments BEFORE STARTING 1 Make sure the generator is positioned on a...

Страница 10: ... 0810 A Bearing The bearing used in the generators is a heavy duty sealed roller bearing requires no maintenance or lubrication B Receptacles Quality receptacles have been utilized If a receptacle should become cracked or otherwise damaged replace it Using cracked or damaged receptacles can be both dangerous to the operator and destructive to the equipment ENGINE FUEL LINE BLEEDING If the engine i...

Страница 11: ...ltage too high a Engine speed too high a Bring generator to a qualified technician for adjustment Generator overheating a Generator is overloaded b Insufficient ventilation a Reduce the load See Load Application section of this manual b Make sure there is at least 3 feet of clearance on all sides of generator No output voltage a Defective load connected to generator b Broken or loose wire c Defect...

Страница 12: ...11 Parts Breakdown Exploded View 165961 Rev B ...

Страница 13: ...tor Assembly 1 11 778123 Generator Mount 1 12 36138 Relay 1 13 32844 Lower Bracket 6 14 778118 Base 1 15 38770 Control Panel Weldment 1 16 82067 Clip Nut 10 32 4 17 778120 Control Panel Assembly 1 18 32769 Nameplate 6500 DPG 1 19 34172 Isomount 6 20 306459 Engine Ground Wire 1 21 32848 Upper Bracket 6 22 778057 HATZ Diesel Engine 1 23 38321 Decal 1 24 777345 Fuel Line 19 25 30755 Fuel Filter 1 26 ...

Страница 14: ...13 Wiring Diagram 778120 1 2 4 3 6 5 ...