    GENERATOR FEATURES

Reference 1 – Generator. The generator

 is

equipped with a high quality brushless generator.   The
generator is maintenance free and will provide years of
dependable service. The neutral is bonded to ground.

Reference 2 - Grounding Screw .  

Ground the

generator via the grounding screw, to a copper  pipe  or
rod  that is  driven into moist  soil.

Reference 3 - Control Panel.  

See Figure 3 for

details.

 

WARNING

 Contact  a  licensed electrician to

wire electrical plugs and/or cord-sets.    Improper  wiring
could result in a fire or electrical shock.

Reference 4 - Vibration Isolation Mounts.  

The

engine and  generator are mounted on  rubber  mounts
that absorb most of the  engine  vibration.   This  feature
eliminates the tendency of the machine to “walk” which
is common with engine powered equipment. If  the
mounts appear damaged, replace with factory
approved parts.

Reference 5 - Oil Drain Plug.  

Removal of plug

allows drainage of oil from the engine. Consult your
Hatz engine manual for further details.

Reference 6 - Oil Filter  Access  Cover.  

Your

Hatz engine is equipped with a reusable oil filter. The
filter should be every 1000 hours of use. Consult your
Hatz engine manual for further details.

Reference 7 - Oil Fill and Dip Stick.   

Consult

your Hatz engine owner’s manual for details
concerning oil change intervals.

Reference 8 - Warning Decal. Nev er 

operate the

generator or engine until all warning labels are  fully
understood.  If warning labels are missing contact our
customer service department at 1-800-270-0810.

Reference 9 - Air Cleaner Housing.  

Refer to the

Hatz engine manual for air cleaner care.

Reference 10 - Recoil Handle.  

Consult your

owner’s manual for engine starting or refer to page 8
of this manual.

Reference 11

 - 

Muffler. Never

 operate  the

generator without the deflector installed in the upright
position.

Reference 12 - - Battery Box.  Warning: Always

wear safety glasses w hen w orking on or near  the
battery. 

The battery box provides protection for  the

battery and will accept a standard lawn  tractor  size
battery (Group  U1-7). The engine  requires  a 12  volt
battery, with a minimum rating of 36 Ah (Amp-hour).
When installing the battery, always  connect the  red
colored (“positive” or “+”) cable first.  When
disconnecting the battery, always  remove  the black
colored (“negative” or “-”) cable first.

 

WARNING

 Sulfuric acid is a corrosive

poison.  Avoid contact with skin, eyes or  clothing.
Always wear safety glasses.

Reference 13 - Decal.   

Decal describes  product

features.

Reference 14 -  6.5 Gallon Fuel Tank.  

Large

tank allows for extended run capabilities.  

Alw ays

allow room for fuel expansion by not filling the  tank
completely full.

Reference 15 - Fuel Cap w ith Gauge.  

The fuel

cap is extra large, creating a large hole for refilling and
a comfortable  grip.

 

You can always monitor the fuel

level without removing the cap by using the fuel level
indicator built into the fuel cap.

          Figure 3  

(Ref. 18-26)

Reference 16 - Main Line Breaker. 

The main  line

breaker is a  two-pole thermo-magnetic  circuit  breaker.
The circuit breaker will protect the generator from
overload and short circuit conditions. To  reset  the
circuit breaker move the toggle to the OFF position,
then back to the ON position.  When this circuit
breaker is in the OFF position, all receptacles will be
off.

Reference 17 - Thermal Circuit Breakers.  

The

control panel has two thermal circuit breakers. If the
circuit breaker trips, a black post will extend from the
circuit breaker, push the black post to reset the circuit
breaker.  If the circuit breaker will not reset,  wait two
minutes and try again.

Reference 18 – 120 Volt-20  Amp  GFCI  Duplex

Receptacle.

  The control panel is equipped with four

120 Volt-20 Amp ground fault circuit interrupt (GFCI)
receptacles (NEMA 5-20R).  The  receptacles  will
accept either NEMA 5-15P or NEMA 5-20P  plugs.  In
the center of each duplex  receptacle  there is  both a
test/reset button and indicator lamp. If there is a fault
condition with a load connected to a duplex receptacle,
the indicator lamp will glow and the reset button will
extend. To test the GFCI press the test  button and  the
reset button should extend.  The  reset  button must  be
pushed to  reset the  receptacle.

 

 

 

 

 

 

 

P O W E R E D  B Y

Содержание 6500 DPG

Страница 1: ...P e r f o r m a n c e MODEL 6500 DPG ITEM 165961 Diesel Portable Generator M165961B OWNER S MANUAL Call Customer Service at 1 800 270 0810 Hours Monday Friday 7 00 AM to 5 00 PM CST Saturday 7 30 AM to 11 30 AM CST ...

Страница 2: ...RTANT Make certain the operator Reads and understands the manuals pertaining to this machine Is instructed in safe and proper operation of this machine NOTICE K BAR Industries Incorporated reserves the right to make improvements in design and or changes in specifications at any time without incurring any obligation to install them on units previously sold TABLE OF CONTENTS Thank you 1 Specificatio...

Страница 3: ...l Capacity 1 76 US quarts 1 65 L Starting Method Electric Recoil 120V Receptacle 20 Amp A Duplex GFCI NEMA 5 20R 30 Amp A Locking NEMA L5 30R 120 240V Receptacle 30 Amp A Locking NEMA L14 30R Circuit Breakers 30 Amp A Magnetic Qty 1 20 Amp A Thermal type Qty 2 Grounding Screw Receives 10 Ga Fork Terminal Battery 12 Volt battery with an ampere hour rating of at least 36 AH Dimensions Length 34 00 8...

Страница 4: ...r 9 Air Cleaner Housing 2 Grounding Screw 10 Recoil Handle 3 Control Panel 11 Muffler 4 Isolation Mounts 12 Battery Box 5 Oil Drain Plug 13 Warning Decals 6 Oil Filter Access Cover 14 6 5 Gallon Fuel Tank 7 Oil Fill and Dip Stick 15 Fuel Cap with Gauge 8 Operation Instructions Figure 2 Ref 10 15 2276 ...

Страница 5: ...l accept a standard lawn tractor size battery Group U1 7 The engine requires a 12 volt battery with a minimum rating of 36 Ah Amp hour When installing the battery always connect the red colored positive or cable first When disconnecting the battery always remove the black colored negative or cable first WARNING Sulfuric acid is a corrosive poison Avoid contact with skin eyes or clothing Always wea...

Страница 6: ... WARNING indicates a potentially hazardous situation which if not avoided could result in a death or serious injury CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices RULES FOR SAFE OPERATIONS Safety precautions are essential when operating this generator Respectful and cautious opera...

Страница 7: ...ion is eliminated and a dead short can result Always compare the generator nameplate data with that of the equipment to be used to ensure that watts volts amperage and frequency requirements are suitable for operating equipment The wattage listed on the equipment nameplate is its rated output However some equipment may require three to ten times more wattage than its rating on the nameplate as the...

Страница 8: ...ing an extension cord with a small wire size Use this chart to estimate the total load on your generator For Determining Generator Load Requirements Device Running Watts Air Conditioner 12 000 Btu 1700 a Battery Charger 20 Amp 500 Belt Sander 3 1000 Chain Saw 1200 Circular Saw 6 1 2 900 Coffee Maker 1000 Compressor 1 HP 2000 a Compressor 3 4 HP 1800 a Compressor 1 2 HP 1400 a Curling Iron 700 Dish...

Страница 9: ... continued and proper operation of the generator The voltage can be checked with a portable voltmeter Frequency can be checked by using a electric clock with a sweep second hand Timed against a wristwatch or stopwatch The clock should be correct within 2 seconds per minute A qualified technician should accomplish engine speed adjustments BEFORE STARTING 1 Make sure the generator is positioned on a...

Страница 10: ... 0810 A Bearing The bearing used in the generators is a heavy duty sealed roller bearing requires no maintenance or lubrication B Receptacles Quality receptacles have been utilized If a receptacle should become cracked or otherwise damaged replace it Using cracked or damaged receptacles can be both dangerous to the operator and destructive to the equipment ENGINE FUEL LINE BLEEDING If the engine i...

Страница 11: ...ltage too high a Engine speed too high a Bring generator to a qualified technician for adjustment Generator overheating a Generator is overloaded b Insufficient ventilation a Reduce the load See Load Application section of this manual b Make sure there is at least 3 feet of clearance on all sides of generator No output voltage a Defective load connected to generator b Broken or loose wire c Defect...

Страница 12: ...11 Parts Breakdown Exploded View 165961 Rev B ...

Страница 13: ...tor Assembly 1 11 778123 Generator Mount 1 12 36138 Relay 1 13 32844 Lower Bracket 6 14 778118 Base 1 15 38770 Control Panel Weldment 1 16 82067 Clip Nut 10 32 4 17 778120 Control Panel Assembly 1 18 32769 Nameplate 6500 DPG 1 19 34172 Isomount 6 20 306459 Engine Ground Wire 1 21 32848 Upper Bracket 6 22 778057 HATZ Diesel Engine 1 23 38321 Decal 1 24 777345 Fuel Line 19 25 30755 Fuel Filter 1 26 ...

Страница 14: ...13 Wiring Diagram 778120 1 2 4 3 6 5 ...