Summary of Important Safety Information for Operation (cont’d)
42
Refueling
. DO NOT refuel the engine until it has cooled at least two minutes.
Malfunction during operation.
Immediately turn off the generator if any of the following conditions arise
during operation:
o
Excessive change in engine speed, slow or fast
o
Overheating in load connecting devices
o
Sparking or arcs from generator
o
Loss of electrical output
o
Receptacle damage
o
Engine misfire
o
Excessive vibration
o
Flame or smoke
o
Abnormal noise
Adjusting / repairing
. Always turn off generator and remove spark plug(s) or spark plug wire(s) before
working on the generator to prevent accidental starting.
Safety – After use
Cool engine before storing.
Let engine cool for at least five minutes before storing. A hot engine can be a
fire hazard.
Shut off fuel supply.
Make sure gasoline shut-off valve is in the OFF position.
Prevent accidental starting.
When generator is not in use, remove key from starter (key start engines) and
secure in a safe location, or remove spark plug(s) in order to ensure that generator cannot be started in a
storage location or by untrained persons.
Storage location.
Store the generator in a dry location away from sources of heat, open flames, sparks or
pilot lights – such as water heaters, space heaters, furnaces, clothes dryers, or other gas appliances – EVEN IF
the generator’s gas tank is empty. Residual gasoline could ignite.
Exercise regularly.
Exercise generator every four weeks to dry out moisture that accumulates in the
windings. If generator cannot be exercised on a regular basis, prepare generator for long term storage.
Periodic maintenance.
Perform periodic maintenance as directed in this manual to keep the generator in safe
working condition.
Safety - Inspection/Maintenance
Inspect and maintain your generator on a regular basis and repair as needed to keep it in safe working condition:
Turn off generator
. Always turn off generator and remove spark plug(s) or spark plug wire(s) before
working on the engine or generator to prevent accidental starting.
Discharge capacitor.
When the generator is shut down, the capacitor may maintain a charge. Always
discharge the capacitor before working on the generator head to prevent electrical shock.
Replace guards / shields.
Make sure all guards and shields are replaced after servicing the generator.
Replacement parts.
If a part needs replacement, only use parts that meet the manufacturer’s specifications.
Replacement parts that do not meet specifications may result in a safety hazard or poor operation of the
generator and will void the warranty.
Содержание 165601
Страница 2: ...Hazard Signal Word Definitions 2 ...
Страница 43: ...Generator Exploded View Rev O 3 Item s 165601 165603 165604 43 ...
Страница 45: ...Generator Exploded View Rev O 3 Item s 165605 165606 165607 45 ...
Страница 47: ...Control Panel Parts List Rev O 3 47 Item 165601 Item 165603 Item 165604 ...
Страница 48: ...Control Panel Parts List Rev O 3 48 Item 165605 Item 165606 Item 165607 ...
Страница 50: ...Generator Head Exploded Views Rev O 3 Item s 165601 165603 165604 165605 50 ...
Страница 52: ...Generator Head Exploded Views Rev O 3 Item s 165606 165607 52 ...
Страница 54: ...54 This page has intentionally been left blank ...
Страница 56: ...56 Assembled by Northern Tool Equipment Company Inc Burnsville MN 55306 NorthernTool com ...