Installation / Initial Set-Up
20
Table 2
Current/Power
Maximum Extension Cord Length
Amps at
240V
Load
(watts)
#10 Ga.
Cord
#12 Ga.
Cord
#14 Ga.
Cord
#16 Ga.
Cord
10
2400
250'
150'
100'
75'
20
4800
125'
75'
50'
25'
30
7200
60'
35'
25'
10'
40
9600
30'
15'
10'
*
50
12000
15'
*
*
*
WARNING:
Use of under sized extension cords can cause electric shock, fire, or
damage to connected devices.
3.
All extension and appliance cords must be in good condition and not
worn, bare, frayed, or otherwise damaged.
WARNING:
Use of damaged electric cords can cause electric shock or fire.
Note: If an extension cord becomes hot to the touch, it is overloaded or
damaged and must be replaced.
Northern Tool is NOT responsible for damage or injury resulting from
customer use of inadequate extension cords.
Содержание 165601
Страница 2: ...Hazard Signal Word Definitions 2 ...
Страница 43: ...Generator Exploded View Rev O 3 Item s 165601 165603 165604 43 ...
Страница 45: ...Generator Exploded View Rev O 3 Item s 165605 165606 165607 45 ...
Страница 47: ...Control Panel Parts List Rev O 3 47 Item 165601 Item 165603 Item 165604 ...
Страница 48: ...Control Panel Parts List Rev O 3 48 Item 165605 Item 165606 Item 165607 ...
Страница 50: ...Generator Head Exploded Views Rev O 3 Item s 165601 165603 165604 165605 50 ...
Страница 52: ...Generator Head Exploded Views Rev O 3 Item s 165606 165607 52 ...
Страница 54: ...54 This page has intentionally been left blank ...
Страница 56: ...56 Assembled by Northern Tool Equipment Company Inc Burnsville MN 55306 NorthernTool com ...