ac Voltage Selector
Facilities Connector
A chassis mounted 15-way D-type socket used to terminate external signal connections. The pin-out of
this connector is detailed in
.
Table 3-2 Facilities Connector (CN1) Pin-Out
Facilities
Connector
Pin
Signal
Input or
Output
Notes
1
2
Audio line L1
Audio line L2
Both
600 ohm balanced audio line. The line carries transmit and
receive audio. Phantom keying is superimposed on the
transmit audio.
3
External PTT
Input or
output
When used as an output, can be used to key the transmitter
as an alternative to phantom keying. When used as an
input, this connection allows an external PTT signal (0 volt
active; 12 volt not keyed) to be used as an alternative to the
front panel microphone PTT. The input can be connected,
for example, to a footswitch.
6
4
7
5
Transmit audio line L1
Transmit audio line L2
Receive audio line L1
Receive audio line L2
Output
Output
Input
Input
600 ohm balanced transmit and receive audio lines.
Phantom keying is superimposed on the transmit audio
lines. These audio lines are used for both phantom keying
and external PTT configurations.
8
9
10
Not used
Not used
Not used
-
-
-
Do not connect to this pin.
Do not connect to this pin.
Do not connect to this pin.
11
12
External dc input +
Ground (dc input -)
Input
Input
Used when the controller is operated from a dc input supply,
or when a dc supply is used as a backup to an ac input
supply.
13
14
Cradle switch
Cradle switch
Input
Input
Optional facility that allows loudspeaker switching when
using a handset cradle. Before using this optional facility,
link LK3 must be removed from the controller's PCB
(see
).
15
Tape/sidetone
Output
Single-ended audio connection at a maximum level of 6 V
peak-to-peak. The output is both transmit and receive
audio.
220
11
0
This component selects between the 110 to 120 Vac input supply
range and the 220 to 240 Vac range.
The correct range must be
selected before the ac supply is connected to the controller.
Between 110 Vac and 120 Vac the selector must be set to 110
Between 220 Vac and 240 Vac the selector must be set to 220.
Содержание T6MC
Страница 1: ...Park Air T6MC Controller User Documentation Back to Disk Menu ...
Страница 15: ...Back to Disk Menu Introduction ...
Страница 19: ...Back to Disk Menu Specification ...
Страница 22: ...Park Air T6MC Controller Page 2 4 Specification Back to Disk Menu Intentionally Blank ...
Страница 23: ...Back to Disk Menu Operation ...
Страница 29: ...Back to Disk Menu Installation ...
Страница 35: ...Back to Disk Menu Maintenance ...
Страница 39: ...Back to Disk Menu Parts List ...
Страница 47: ...Back to Disk Menu Figures ...