Operation
Rear Panel Controls and Connectors
The following paragraphs describe the function of all rear panel controls and connectors.
Fig 3-1 T6MC Controller Rear Panel
Power Switch
When the Power switch is set to the Standby position, dangerous voltage is still present in
the controller's internal power supply circuitry. To ensure safe working during maintenance,
the controller must be isolated from the ac and dc input supplies.
A two-way rocker switch is used to connect (On position) and disconnect (Standby position) the internal
power supplies to the controller's circuits.
ac Input Connector
A chassis mounted 3-pin plug for the ac input supply (see
). This plug has an integral fuse. The
values of the ac fuses are shown below. Note that the fuses are safety critical items (see
).
For 110 to 120 Vac range, 20 mm, 125 mA anti-surge, Park Air part number 29F01490102S.
For 220 to 240 Vac range, 20 mm, 63 mA anti-surge, Park Air part number 29F01480102S.
Fig 3-2 Chassis Mounted ac Connector
Rear View
AC INPUT
F1
POWER
FACILITIES
DISCONNECT
FROM MAINS
WHEN NOT IN USE
!
220
11
0
WARNING Dangerous Voltage
= Standby
= On
FS2
Line
Earth
Neutral
Содержание T6MC
Страница 1: ...Park Air T6MC Controller User Documentation Back to Disk Menu ...
Страница 15: ...Back to Disk Menu Introduction ...
Страница 19: ...Back to Disk Menu Specification ...
Страница 22: ...Park Air T6MC Controller Page 2 4 Specification Back to Disk Menu Intentionally Blank ...
Страница 23: ...Back to Disk Menu Operation ...
Страница 29: ...Back to Disk Menu Installation ...
Страница 35: ...Back to Disk Menu Maintenance ...
Страница 39: ...Back to Disk Menu Parts List ...
Страница 47: ...Back to Disk Menu Figures ...