T6-D-USER-RV-EN
Page 7-6
Connector information
© Park Air Systems Limited 2017
Connector
Connection
Earth stud
M5 thread
Note:
The radio is attached by the earth connection to the fixing-lug in the Park Air C4 cabinet.
This
must
be attached.
Failure to comply with this instruction will result in non-compliance with the EMC Directive 2014/30/EU.
Connector
Connection
Characteristics
AC input
IEC-C16
chassis plug
Neutral
Input supply: 99 to 264 V AC. Frequency: 47 to 63 Hz.
No more than 55 VA under any condition.
Earth
Live
Note:
The connections are shown as viewed on the rear panel of the radio.
The protective earthing connector (earth) must be connected.
The cable used to connect between the equipment and the user’s AC power source must be 3-core (to IEC 227) rated 250 VAC at
8 amps, and have a minimum cross-sectional area of 1.0 mm
2
per core. Northrop Grumman recommends the use of polyvinyl
chloride (PVC) insulated cable. The cable must be fitted with the IEC approved equipment connector and conform to this
specification:
If PVC insulated, be not lighter than ordinary polyvinyl chloride sheathed flexible cord according to IEC publication 227
(designation H05 VV-F, H05 VVH2-F). For North America the cable must be UL listed/CSA recognised.
If rubber insulated, be of synthetic rubber and not lighter than ordinary tough rubber-sheathed flexible cord according to
IEC publication 245 titled ‘Rubber Insulated Cables of Rated Voltage up to and including 450/750 V’ (designation H05 RR-F).
Connector
Connection
Characteristics
DC input
Saf-D-Grid
chassis plug
Pove
Input supply: 21 to 32 V DC.
No more than 55 W under any condition.
Not connected
Negative -ve
Note:
The connections are shown as viewed on the rear panel of the radio.
The DC supply input protects against reverse polarity connection.
The DC supply cable must have a minimum cross-sectional area of 1.5 mm
2
or 14 AWG per core. If PVC insulated, be not lighter
than ordinary polyvinyl chloride sheathed flexible cord according to IEC publication 227 (designation H05 VV-F, H05 VVH2-F). For
North America the cable must be UL listed/CSA recognised.
Содержание Park Air T6-RV
Страница 1: ...PRODUCT CODE TITLE Park Air T6 RV VHF Receiver User Documentation T6 D USER RV EN ...
Страница 44: ...T6 D USER RV EN Page 4 10 Front panel operation Park Air Systems Limited 2017 Intentionally blank ...
Страница 54: ...T6 D USER RV EN Page 5 10 Web server operation Park Air Systems Limited 2017 Intentionally blank ...
Страница 66: ...T6 D USER RV EN Page 7 8 Connector information Park Air Systems Limited 2017 Intentionally blank ...
Страница 70: ...T6 D USER RV EN Page 9 2 Associated equipment Park Air Systems Limited 2017 Intentionally blank ...