NORTHMARK YDE2800X/E Скачать руководство пользователя страница 3

 
 

WARNING 

1. TO PREVENT THE FIRE 

Never add fuel to the fuel tank while the engine is running. 

Wipe off the overflowed fuel oil with a clean cloth. Keep explosives and other flammable products away 

from the generating set. 

 

  To prevent the fire and to provide adequate ventilation, keep the generating set at least one meter 

away from buildings and other equipment during operation. 

  Operate the generating set on a level surface. 

  Do not put the generating set indoors while the engine is hot. 

  Set up extinguisher and first-aid kit in working field. 

 

2. TO PREVENT FROM INHALING THE EXHAUST 

Exhaust  gas  contains  poisonous  carbon  monoxide,  which  is  harmful  to  the  health.  Never  use  the 

generating set at the confined places or poor ventilated locations. If it's necessary to run the generating 

set indoors, be sure to provide the adequate ventilation. 

 

3. BE CARE NOT TO BE SCALDED 

The muffler and the engine body are very hot while the engine is running or just after running, do not 

touch these parts to prevent from being scalded. 

  Please note the    warning labels on the generator. 

 

4. ELECTRIC SHOCKS, SHORT DIRCUITS 

To avoid electric shocks or short circuits, do not touch the generating set when your hands are wet. This 

generating  set  is  not  waterproof,  so  it  should  not  be  used  in  a  place  exposed  to  rain  snow  or  water 

sprays.  Use  of  the  generating  set  in  a  wet  place  can  cause  short  circuits  and  electric  shocks  during 

operation. 

 

  The generating set should be grounded to prevent electrical shocks from faulty appliances. Connect 

a length of heavy wires between the generating sets ground terminal and an external ground source. 

  Do  not  hook  up  tools  or  other  apparatus  to  generating  set  rotator  before  it  has  been  started.  lf 

equipment is attached, generator starting may cause sudden movements of the equipment and result in 

injuries and accidents. Be Sure to disconnect any apparatus from the generating set or prior to starting. 

 

 

Содержание YDE2800X/E

Страница 1: ...USER MANUAL PORTABLE DIESEL GENERATOR SET Please read the manual carefully before using the engine This guide contains important guidance for safe operation...

Страница 2: ...y source of ignition away from fuel tank at all times WARNING lndicates that the severe personal injury even death will result if the instructions are not followed CAUTION lndicates that the severe pe...

Страница 3: ...E SCALDED The muffler and the engine body are very hot while the engine is running or just after running do not touch these parts to prevent from being scalded Please note the warning labels on the ge...

Страница 4: ...t enough need to charge Red the electrolyte is not enough need to change Battery usage Shut down the power after removing the battery negative wire when checking and maintaining generator Connect batt...

Страница 5: ...2 Configuration 9 3 Preparation for Starting 11 4 Start the Generating Set 15 5 Operate the Generating Set 19 6 Load 20 7 Stop the Generating Set 23 8 Periodic Checks and Service 24 9 Long term Stora...

Страница 6: ...ut 12V 8 3A Coupling method Transmission rigid connection Model YD173FA YD178FA Engine Type 4 stroke single cylinder air cooled direct injection diesel engine Displacement ml 211 296 Bore x stroke mm...

Страница 7: ...pling method Transmission rigid connection Model YD186FAG Engine Type 4 stroke single cylinder air cooled direct injection diesel engine Displacement L 0 418 Bore x stroke mm 86 72 Lube oil capacity L...

Страница 8: ...oupling method Transmission rigid connection Model YD188FAG Engine Type 4 stroke single cylinder air cooled direct injection diesel engine Displacement L 0 456 Bore x stroke mm 88 75 Lube oil capacity...

Страница 9: ...r min 8 2 Fuel type Diesel 0 summer 10 winter 35 chilling Lube oil brand L ECD grade 15W30 15W40 Generating Set Low oil alarm system With Fuel tank capacity L E E3 12 5 T TD T3 TD3 14 5 Overall dimens...

Страница 10: ...GURATION a Parts Illustration YDE SERIES X E X3 E3 Fuel tank Air cleaner Control panel Recoil starter Decompression lever Starting handle Engine speed lever Oil dipstick Oil drain plug Fuel filler cap...

Страница 11: ...1 0 b Parts Illustration YDE series T T3 TD TD3 Fuel filler cap Lifting hook Control panel Brake Maintenance door Muffler exhaust outlet Heat outlet Access door...

Страница 12: ...ll ventilated area with the engine stopped Do not smoke or allow flames or sparks in the area where the engine is refueled or where the fuel oil stored Do not overfill the tank make sure the filler ca...

Страница 13: ...ly the risk of piston seizure piston ring sticking and accelerated wear of the cylinder liner bearing and other moving components increases significantly So the generating set life will be shortened N...

Страница 14: ...h should always be kept in the ON position during operation Before starting the engine be sure to turn the switches of the working instrument lighting apparatus motor etc to their OFF position If the...

Страница 15: ...mends to run the engine at 3000r min with 50 load in break in period Replace the engine oil on time Replace the engine oil while the engine is warm after 20 hours running the old engine oil will be dr...

Страница 16: ...ompression lever It will return automatically when the recoil starter is pulled Pull out the recoil starter handle briskly with both hands CAUTION Do not allow the handle grip to snap back against the...

Страница 17: ...1 6 Recoil starting...

Страница 18: ...1 7 Recoil starting...

Страница 19: ...position Remove your hand from the key as soon as the engine starts If the starting motor does not start after 10 seconds wait 15 seconds before starting it again CAUTION Run the starting motor for l...

Страница 20: ...ine oil Check the oil level and refill Do not loosen or readjust either the engine speed limiting bolt or fuel injection limiting bolt otherwise the performance will be affected 5 2 Checks during the...

Страница 21: ...duty motors If the operation is false the generating set will lag or stop suddenly lt is necessary to unload the generating set immediately and turn off the main switch and do checks 5 Three phase gen...

Страница 22: ...minals separately Do not confuse them otherwise the battery and generating set will burn out Do not connect the positive pole of the battery with its negative pole otherwise the generating set damage...

Страница 23: ...tus to the generator set TYPE WATTAGE TYPICAL APPLIANCE EXAMPLE STARTING RATED APPLIANCE STARTING RATED Incandescent lamp Heating appliance X1 X1 Incandescent lamp TV Incandesce nt lamp 100W 100VA W 1...

Страница 24: ...tric starter turn the key to OFF Turn the fuel cock lever to S position Pull out the recoil starter handle until you feel resistance at this position both intake exhaust valve are closed and leave the...

Страница 25: ...ear or 1000 Hrs Check and refill fuel oil Drain out fuel oil Check and refill engine oil Check for oil leakage Check and tighten fastening parts Tighten the cylinder head bolts Replace engine oil Firs...

Страница 26: ...2 Clean the engine oil filter Cleaning time Every 6 months or 500 hours Replace if necessary 8 3 Replace the air cleaner element Replace time Every 6 months or 500 hours CAUTION Never run the engine...

Страница 27: ...k the injection nozzle and fuel injection pump 1 Adjust the clearance of the intake exhaust valves 2 Grind the intake exhaust valves 3 Replace the piston ring All these operations require special tool...

Страница 28: ...Push the decompression lever down Non compression position and hold it while you puIl the recoiI starter2 3 times Do not start the engine Electric starting Turn the engine 2 3 seconds with the decompr...

Страница 29: ...specified oil level should be between the upper level and lower level The nozzle has dirty Clean the nozzle The speed and force to pull the recoil starter are not enough Start the engine according to...

Страница 30: ...ing formula you can calculate the value of the potential e The relations among of the allowable current and length section of the Insulating cable single core multi core are as follow Presume that the...

Страница 31: ...5 0 73 0 71 0 69 0 66 3000 0 64 0 62 0 6 0 58 0 56 4000 0 54 0 52 0 5 0 48 0 46 Note When the relative humidity is 60 the modified coefficient is C 0 01 When the relative humidity is 80 the modified c...