23
7. STOP YOUR GENERATlNG SET
1. Disconnect the load from the generating set.
2. Turn off the air switch of the generating set.
3. Set the speed lever at "RUN" position, run the
generating set without load for about 3 minutes. Do not
stop the engine suddenly, otherwise the temperature wiIl
increase abnormally, the nozzle will block and the
generating set will be damaged.
■
Press down the stop lever.
■
Concerning the electric starter, turn the key to "OFF".
■
Turn the fuel cock lever to "S" position.
■
Pull out the recoil starter handle until you feel
resistance (at this position, both, intake/exhaust valve are
closed.) and leave the handle in this position. This
prevents the engine from rust.
WARNING
■
If the engine keep on running even after the speed lever is placed at the "STOP" position, either turn
the fuel cock to the "CLOSE" position or loosen the nut of high pressure fuel pipe on the pump side to
stop the engine.
■
Do not stop the engine with the decompression lever.
■
Do not stop the generating set with load. Stop if after the load removed.