Northland Crown Royal 1000 Скачать руководство пользователя страница 11

InsTallaTIon

Pristine series installation and oPeration Manual • 2011 

9

identifying Main Components 

(see drawings on page 8)

no. description

1

Baffle

2

Red Indicator Light

3

On/Off Switch

4

Temperature Control

5

Loading Door

6

Latch Catch

7

Ash Clean Out Door

8

Ash Tray

9

Secondary Burn Chamber

10

Heat Exchange Flues

11

Door Lock Bar

12

Exhaust Exit Lever

13

Vent Cap & Water Level Indicator

14

Moulded Brick

15

S 70 Brick

16

1/2 Brick

17

Fire Brick

18

Smoke Exit Connector Bar

19

Switch Trigger

20

Air Gate

21

Overflow

22

Side Panel

23

Smoke Exit Connector Bar

24

Smoke Exit Lid

25

Extension Leg (optional)

26

Leg Brace (optional)

27

Ash Rake

28

Flue Cleaning Rods

29

Flue Cleaning Brush

30

Electric Element Ports

31

Return Port

32

Drain

33

Burner Mount Cover

34

Supply Port

35

Blower

36

Timer

37

Exhaust Area

38

Flapper Unit

39

Exhaust Flange

40

Relays

41

Limit Switches

42

Lifting Hook

43

Top Panel

44

Low Water Cut Off Port/Probe Well B

45

Snap Disc/Furnace Manual Reset

46

Temperature Probe Well A

47

Pump Snap Disc

48

Probe Port

49

Flue Clean Out Cover

50

Rear Access Cover

51

Furnace Electrical Plug

52

Pump Plug

optional: low water cut off switch kit. ask your dealer for details.

Minimum Clearance to Combustibles

Side Wall to Furnace

12” (305 mm)

Back Wall to Furnace

12” (305 mm)

Front of Furnace to Combustibles

48” (1220 mm)

Flue Pipe

12” (305 mm)

Ceiling to Furnace

24” (610 mm)

Floor

0” (0 mm)

installation requirements

1.  The Pristine must be installed on a level stable surface, 

preferably on a concrete floor but may be installed on 

a combustible floor provided that a noncombustible liner 

(such as sheet metal or masonry) be placed on the floor, 

ensuring the following areas are covered to catch stray 

embers:

  -  Underneath the furnace; 

  - At least 16” (406 mm) in front and 8” (203 mm) on 

either side of the fuel loading and ash removal doors; 

 - Underneath the chimney connector and extending 

at least 2” (50 mm) on either side of the chimney 

connector.

2.  Adhere to minimum clearance to combustibles as stated 

in this manual and in accordance with local, state, 

provincial and federal building and fire codes. 

3.  Install in a large open area when possible. Minimum 

enclosed, not well vented, room size is 100 square feet 

(9.3m

2

).

4.  Room must be vented to outside air, see page 11.

iMPortant:

 Contact an insurance provider prior to 

installation to ensure that installation is in compliance with 

local insurance requirements and all terms have been met.

Содержание Crown Royal 1000

Страница 1: ...Installation and Operation Instructions Crown Royal Stoves Pristine Series Model 1000...

Страница 2: ......

Страница 3: ...himney Installation 10 Supplying Make Up Air 11 Water Line Hookup 11 Circulating Pump Electrical Hookup 11 Furnace Electrical Hookup 11 Typical Installation 12 Hookup to the Existing Heat System Water...

Страница 4: ...Fire Brick and Insulation 19 Blower Draft Setting 20 Doors 20 Exhaust Exit Lever Operation 20 Power Outages 20 Operation Do s and Don ts 20 Maintenance 21 During Heating Season 21 End of Heating Seas...

Страница 5: ...d wood gasification to produce highly efficient combustion in the furnace s dual burn chambers 1 Wood in the firebox burns from the bottom up drying the top layer of wood in the firebox and forcing ga...

Страница 6: ...91 De ULC 2006 Norme C22 2 No 3 Certi ed as an add on model February 2010 Floor May be installed on a well constructed combustible oor A noncombustible liner must be placed underneath the furnace at l...

Страница 7: ...must be off for normal operation DO NOT operate with loading door open ASH DOOR ALWAYS OPEN SLOWLY 1 ALWAYS switch furnace off before opening door DO NOT operate with ash removal door open 2 CLOSE and...

Страница 8: ...ndicates a potentially hazardous situation that if not avoided COULD result in death or serious injury if proper precautions are not taken CAUTION CAUTION Indicates a potentially hazardous situation t...

Страница 9: ...e furnace at least 16 406 mm in front and 8 203 mm on either side of the fuel loading and ash removel doors underneath the chimney connector and extending at least 2 50 mm on either side of the chimne...

Страница 10: ...nd Operation Manual 2011 Identifying Main Components see list of components on page 9 13 1 3 4 2 5 6 7 8 9 10 11 12 17 16 15 14 42 43 38 39 37 36 10 35 41 40 20 13 19 18 30 31 32 33 34 22 27 28 29 26...

Страница 11: ...Pump Plug Optional Low water cut off switch kit Ask your dealer for details Minimum Clearance to Combustibles Side Wall to Furnace 12 305 mm Back Wall to Furnace 12 305 mm Front of Furnace to Combusti...

Страница 12: ...instructions to re install the switch trigger remove the control front plate to view the inside of the control box guide the switch trigger into the 2 slots next to the limit switches 3 Remove the si...

Страница 13: ...and therefore no additional make up air is required 5 For a confined space or an unconfined space in a building with unusually tight construction an addition al source of make up air is required Plea...

Страница 14: ...nufacturing warranty covers the Pristine furnace only and does not include anything outside of the Pristine furnace Northland Distributing and Manufacturing takes NO responsibility for installations T...

Страница 15: ...parately from the furnace 7 The existing thermostat should be set several degrees lower than the new thermostat This will allow the regular system to cut in should the Pristine run out of wood and the...

Страница 16: ...m loop and side arm as low as possible PUMP BALL VALVE THERMOMETER BOILER DRAIN TEMPERING OR MIXING VALVE SYMBOLS INDEX Have a qualified electrician check to ensure changes or modifications are made i...

Страница 17: ...ace runs out of wood Figure 3 Note The existing furnace functions as a standby The aquastat on the standby furnace should be turned lower than the aquastat on the Pristine Auxiliary Heat Water to Wate...

Страница 18: ...From indoor furnace Figure 1 Figure 2 To furnace From furnace From pool or spa 110 white 110 black Immersion control Black wire 24 V lines POOL HEATER Bypass 24 V Transformer To pool or spa Common He...

Страница 19: ...shows 1 2 full shut the drain valve shut off water and disconnect the garden hose Note hot water level is higher than cold water level 7 Heatfurnacetooperatingtemperature see Starting the Fire below C...

Страница 20: ...nerally speaking when burning extremely dry firewood pieces should be over 5 12 7 cm in diameter If using high moisture wood use pieces that are less than 5 12 7 cm in diameter It is good to mix the d...

Страница 21: ...sh be too difficult to push through then first push the rod through without the brush 4 Inspect and clean any buildup in the exhaust area 5 Replace covers Secure rear access cover with screws 6 Open a...

Страница 22: ...t 2 Do not force the loading door open beyond the stop Power Outages The Pristine furnace unlike a gas or oil fired appliance does not stop generating heat when the power is interrupted even though th...

Страница 23: ...te a thin black coating in the firebox is acceptable but ensure that there is no ash in contact with bare metal 2 Check for damaged brick and replace as necessary Contact your dealer for replacement b...

Страница 24: ...owing messages will be shown Er Memory error Short circuit probe error Open probe error DTS Technical Data Accuracy 1 Output 16 Amp 1HP 240 Vac SPDT relay Supply voltage 115 Vac 10 Display 3 digit red...

Страница 25: ...Reference Pristine Series Installation and Operation Manual 2011 23 CAUTION DO NOT CONNECT THE ELECTRICAL COMPONENTS OF THIS UNIT TO ANY OTHER ELECTRICAL APPLIANCE...

Страница 26: ...x 36 cm Flue Collar Diameter 6 in 15 cm Log Length 24 in 61 cm Log Diameter 6 in 15 cm Furnace Weight 945 lb 429 kg Water Capacity 60 US Gal 227 L Features Model 1000 Electric Element Optional Wide A...

Страница 27: ...firebox floor The air then exits the firebox without causing the wood to burn Use seasoned wood Cut wetter pieces 8 inches 20 cm shorter than the firebox and load the logs centered in the firebox Spl...

Страница 28: ...more of the following a bad connection a faulty pump snap disc temperature is set too low valves are closed air is in the system or the water level is low Check for loose connections replace snap dis...

Страница 29: ......

Страница 30: ...en followed The Warranty Registration and a copy of the original bill invoice must be forwarded to Northland within thirty 30 days of the date of purchase to validate the warranty Issue Date June 2011...