NVR4POE / NVR8POE Quick Operation Guide
6
For DC load, the jumpers can be used within the limit of 12V/1A safely.
To connect an AC load, jumpers should be left open (you must remove the jumper on the motherboard in the
NVR). Use an external relay for safety (as shown in the figure above).
There are 4 jumpers (JP1, JP2, JP3, and JP4) on the motherboard, each corresponding with one alarm output. By
default, jumpers are connected. To connect an AC load, jumpers should be removed.
Example:
If you connect an AC load to the alarm output 3 of the NVR, then you must remove the JP 3.
Using of Alarm Connectors
To connect alarm devices to the NVR:
1.
Disconnect
pluggable block
from the ALARM IN /ALARM OUT terminal block.
2.
Unfasten stop screws from the
pluggable block
, insert signal cables into slots and fasten stop screws. Ensure
signal cables are in tight.
3.
Connect
pluggable block
back into terminal block.