ONL773LW3 11/13
10
Control Panel
Figure 3:
Series 1-B Generator Control Panel
1. SHUTDOWN BYPASS-PREHEAT SWITCH
There are two functions built into this switch:
preheating the engine and bypassing the engine safety
shutdown circuit, enabling a quicker start. Hold the
switch in the ON position for approximately 10 to 20
seconds before starting a cold engine. Holding the
switch ON for too long can burn out the glow plugs.
NOTE: Three position Engine Control switches must be
in the RUN position during preheating. Preheat switch
must be held in ON position during starting.
2. ENGINE CONTROL SWITCH
To start the engine, hold this switch in the START
position until the engine is running.
After the engine starts, release the switch and it will
return to RUN position. To stop the engine, hold the
switch in the STOP position.
NOTE: The rocker switch has a light that glows when
the set is running.
3. HOUR METER
Keeps track of engine running time.
Содержание NL773LW3
Страница 33: ......