![Northern Lights Lugger M773LW3 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/northern-lights/lugger-m773lw3/lugger-m773lw3_operators-manual_1708505027.webp)
OM773LW3 11/20
25
Troubleshooting
ENGINE
PROBLEM
POSSIBLE CAUSE
RECOMMENDATION(S)
Engine Hard to Start
Improper starting procedure
• See starting section of this manual. Take
or Will Not Start
special note of Bypass Switch operation.
No fuel
• Check level of fuel in fuel tank.
Low battery output
• Check electrolyte level and condition.
Excessive resistance
• Clean and tighten all battery connections.
in starting circuit
Crankcase oil too heavy
• Use oil of proper viscosity.
Improper type of fuel
• Consult fuel supplier and use proper type
of fuel for operating condition.
Water, dirt or air in fuel system
• Drain, flush, fill and bleed system.
Clogged primary
• Clean or replace filter element.
fuel filter element
Clogged secondary
• Replace filter element.
fuel filter element
Dirty or faulty injection nozzles
• Have your dealer check injection nozzles.
Fuel injected but no ignition
• Glow plug malfunction
• Low cylinder compression pressure
Engine Runs Irregularly
Below normal engine temperature • Remove and check thermostat.
or Stalls Frequently
Clogged primary
• Clean or replace filter element.
fuel filter element
Clogged secondary
• Replace secondary filter element.
fuel filter element
Water or dirt in the fuel system
• Drain, flush, fill and bleed system.
Dirty or faulty injection nozzles
• Have your dealer check injection nozzles.
Air in fuel system
• Inspect clamps and hoses on suction side
of fuel pump for air leak.
Improper type of fuel
• Consult fuel supplier and use proper type
of fuel for operating condition.
Low idle, not stable
• Uneven cylinder compression
Lack of Engine Power
Intake air restriction
• Service air cleaner.
• If in sound enclosure - ensure proper
position of snorkle hose
Clogged primary or secondary
• Clean or replace filter element.
fuel filter element
Improper type of fuel
• Consult fuel supplier and use proper type of
fuel for operating conditions.
Overheated engine
• See “Engine Overheats” in next category.
Updated 2-10-20
Содержание Lugger M773LW3
Страница 1: ...OPERATOR S MANUAL OPERATOR S MANUAL OM773LW3 For Model M773LW3 and M773LW3G www northern lights com...
Страница 11: ...OM773LW3 11 20 9 Notes...
Страница 31: ...OM773LW3 11 20 29 Troubleshooting Notes...
Страница 37: ...OM773LW3 11 20 35 DC Wiring Diagrams Updated 10 8 20 DC Wiring Diagram M773LW 12 VDC Isolated Ground B 10835D...
Страница 45: ...OM773LW3 11 20 43 Panel Wiring Diagram S 1 Panel B Deutsch A 12798B Updated 8 22 19 Panel Wiring Diagrams...
Страница 46: ...OM773LW3 11 20 44 Panel Wiring Diagrams Panel Wiring Diagram S 1B Panel B A 12791C Updated 8 22 19...
Страница 57: ......