CAUTION:
When attaching wires to the motor or solenoid terminals, hold the inner nut with
a wrench while tightening the outer nut with a second wrench. Do not allow the terminals to rotate in
their housings. Rotation may cause internal wire damage or part misalignment.
For normal self-recovery work, your vehicle’s existing electrical system is adequate. A fully charged
battery and proper connections are essential. Run the vehicle engine during winching operations to
keep battery charged.
Pay close attention to proper electrical cable connection as follows (refer to Diagram 1)
1. Short Red cable (B') connects to the red terminal (B) of the motor.
2. Short black cable with yellow jacket (C') connects to the yellow terminal (C) of the motor.
3. Short black cable with black jacket (D') connects to the black terminal (D) of the motor.
4. Thin black cable (E) connects to bottom terminal (A) of the motor.
5. Long Black Cable (1.8m), one terminal connects to the bottom terminal (A) of the motor, and
the other terminal negative (-) connects to negative (-) terminal of battery.
6. Long red cable positive (+) connects to positive (+) terminal of battery.
Diagram1: Instruction of connecting cable