 Do not leave this burner unattended while it is lit or heating.

 Monitor  the  burner  when  hot  and  after  use  (temperatures 
above 100°F/38°C). Heated liquid and equipment can remain at 
scalding temperatures long after the boil has ended and burner 
has been shut off.

 Do not exceed 125 lbs 

Do not use this burner for heating oil or grease.

 Keep  children,  pets  and  unauthorized  persons  away  from  the 
Dark Star

®

 2.0 Burner at all times.

 Always operate the burner on a level, stable, noncombustible 
surface such as brick or concrete. Surfaces not suitable for use 
include wood, asphalt or plastic which may burn, blister or melt.

 This burner is for outdoor use only. Do not use in a building, 
garage, tent or any other enclosed area. Do not use in or on a 
recreational vehicle or boat.

 Do  not  locate  this  burner  under  any  overhead  construction. 
Keep  a  minimum  clearance  of  10  ft.  (3.05m)  from  the  sides, 
front and back of the burner to any construction. Keep the area 
clear of any combustible material. Do not use on or under any 
apartment or condo balcony or deck.

 Do not allow the flame to roll past the bottom of the brew kettle.

 Never lift or move a full kettle of water onto or off of the Dark 
Star

®

 2.0 Burner.

 Only use the propane tank valve as the gas shutoff. Do not use 
the regulator.

 A 20-pound (9 kg) propane cylinder should be used with this burner. 
The LP-gas supply cylinder used must have a protective collar and 
must be constructed and marked in accordance with the specifications 
for LP-gas cylinders of the U.S. Department of Transportation (DOT), 
cylinders,  spheres  and  tubes  for  the  transportation  of  Dangerous 
Goods. Do not store a spare LP-gas cylinder indoors, or under or 
near the Dark Star

®

 2.0 Burner. Never fill the cylinder beyond 80% 

full. For proper vapor withdrawal, the 20 lb. (9 kg) cylinder should 
be used in the proper upright position. Cylinder must be turned off 
while not in use. Failure to follow these instructions and warnings 
could result in fire or explosion which could cause property damage, 
personal injury or death.

 Keep the gas supply hose away from heated surfaces at all times.

Ensure all connections are tightly secured before each use.

 Check  for  gas  leaks  before  each  use—this  can  be  done  by 
applying soapy water and looking for bubbles.

 This burner gets dangerously hot while in use. Use well-insulated 
protective  gloves,  clothing  and  boots  during  operation  for 
protection from hot surfaces or splatter from hot liquids. Safety 
goggles are also recommended to protect you from splatter.

Allow the burner to cool to 100°F (38°C) before moving or storing.

 The installation of this burner must conform with local codes or, 
in the absence of local codes, with the National Fuel Gas Code, 
ANSI Z223.1/NFPA 54, Storage and Handling of Liquefied Petroleum 
Gases, ANSI/NFPA 58, Natural Gas and Propane Installation Code, 
CSA B149.1, Propane Storage and Handling, CSA B149.2, or the 
Standard for Recreational Vehicles, ANSI A119.2/NFPA 1192 and 
the Recreational Vehicle Code, CSA z240 RV Series

 If you smell gas: Shut off gas to the burner, extinguish any open 
flame, and if odor continues, keep away from the burner and 
gas cylinder and immediately call your fire department.

 Never  use  a  gas  cylinder  if  it  shows  signs  of  dents,  gouges, 
bulges, fire damage, erosion, leakage, excessive rust, or other 
forms of visible external damage. The cylinder may be hazardous 
and should be checked by a qualified liquid propane supplier.

 If a fire should occur, keep away from the burner and immediately 
call your Fire department. 

 When burner is in use, have a type BC or ABC fire extinguisher 
readily  available.  A  type  BC  or  ABC  fire  extinguisher  may,  in 
some circumstances, contain the fire.

 DO NOT use external electrical sources with this burner.

 Do not attempt to disconnect the regulator hose assembly while 
burner is in operation.

 When burner use is complete, always turn the LP cylinder valve 
OFF  first,  then  turn  the  regulator  control  valve  OFF.  Turning 
the  cylinder  OFF  first  allows  remaining  gas  to  flow  out  of  the 
regulator  hose  assembly  before  the  regulator  control  valve  is 
turned OFF.

WARNING

READ AND UNDERSTAND BEFORE USING THIS PRODUCT

TECHNICAL DETAILS

Product

Dark Star® Burner

Output

65,000 BTU

Description

High Pressure Burner

Height of Burner

13.4 inches

Size

18 x 18.1 x 13.4 inches

Burner Surface Diameter

18 inches

Weight (Net weight)

12.5 lbs

Pressure

Cylinder Pressure