8.0
SCBA STORAGE
8.1 SCBA STORAGE
8.1.1
Complete routine checks and inspection procedures outlined in Section 3.3 of these User’s
Instructions.
8.1.2
Ensure that complete apparatus is clean and dry.
8.1.3
Ensure that the bypass knob is in the CLOSED position.
8.1.4
Ensure that the head harness straps are fully extended on the facepiece. Connect CDV into
the facepiece or hood assembly and store in case, positioned to avoid distortion.
8.1.5
Ensure that shoulder and waist belt straps are fully extended.
8.1.6
Place the complete apparatus in the storage case or suitable storage place so it can be easily
reached for emergency use.
8.1.7 MOUNTING SCBA:
When storing SCBA using mounting brackets, ensure that brackets are
secure and that no sharp objects will come in contact with SCBA or cylinder.
8.1.8
If you have the First Breath CDV, push button "in" to set first breath.
9.0
USER MAINTENANCE
9.1
CYLINDER FILLING PROCEDURES
9.1.1
Basic cylinder inspection shall include:
A.
Inspect gauge for damage.
B.
Inspect cylinder for mechanical damage (cracks, dents, gouges) or signs of heat or
chemical damage. (Refer to CGA C-6.2 "Guideline for Visual Inspection and
Requalification of Fiber Reinforced High Pressure Cylinders" for all wrapped cylinders.)
C.
Check that hydrostatic test date on cylinder is current.
D.
Check that cylinder valve threads are not damaged.
E.
Check that the valve body is not bent.
F.
Check that the burst disc outlet is clean and free of debris.
G.
If any item listed above is noted, depressurize the cylinder to a slight positive pressure,
tag, and take out of service.
9.1.2
Prior to filling the cylinder, follow the basic inspection procedures outlined in 9.1.1
9.1.3
Cylinder air shall meet or exceed the standards in CGA G 7.1 Grade D or higher.
18
Cylinders that are tagged for repair should always be stored empty with the cylinder valve closed
to prevent contamination or condensation inside the cylinder.
CAUTION
Содержание FRONTIER Series
Страница 27: ...27 ...