background image

drain fitting

on valve

TO

floor

drain

valve

drain

hose

1--1/2” AIR GAP

8

"

If making a soldered copper installation,

do all

sweat soldering before connecting pipes to the

softener fittings.

Torch heat will damage plastic

parts.

"

When turning threaded pipe fittings onto plastic

fittings, use care not to cross--thread.

"

Use pipe joint compound on all external pipe

threads.

"

Support inlet and outlet plumbing in some man-

ner (use pipe hangers) to keep the weight off of the

valve fittings.

5.

INSTALL GROUNDING WIRE (IF NEED-

ED):

"

To maintain electrical ground continuity in the

house cold water piping, install a #4 copper wire

across the removed pipe section, securely clamping

it at both ends (see Figure 2) -- parts not included.

NOTE:

A 3--valve bypass system maintains ground

continuity.

FIGURE 2

ground wire

inlet -- outlet

pipes

hose clamp

ground (2)

6.

CONNECT AND RUN THE

VALVE

DRAIN

HOSE:

"

Take a length of 3/8” or 7/16” inside diameter

hose and attach to the valve drain fitting. So water

pressure does not blow the hose off, use a hose

clamp to secure in place.

"

Locate the other end of the hose at a suitable

drain point...floor drain, sump, laundry tub, etc.

Check and comply with local codes.

IMPORTANT: Use high quality, thick--wall hose that

will not easily kink or collapse.

The water softener

will not work if water cannot exit this hose during re-

generations.

"

Tie or wire the hose in

place at the drain point.

Water pressure will cause

it to whip during the back-

wash and fast rinse cycles

of regeneration. Also pro-

vide an air gap of at least

1--1/2” between the end of

the hose and the drain

point. An air gap prevents

possible

siphoning

of

sewer water, into the soft-

ener, if the sewer should

‘‘back--up’’.

"

If raising the drain

hose overhead is required

to get to the drain point,

do

not raise higher than 8’

above the floor

. Elevat-

ing the hose may cause a

back--pressure that could

reduce brine draw during

regenerations.

CONNECTING A RIGID VALVE DRAIN TUBE

To adapt a copper drain tube to the softener, use a

hacksaw to cut the barbed end from the drain fitting as

shown. Buy a compression fitting (1/4” female pipe

thread x 1/2”O.D. tube) and needed tubing from your

local hardware store.

FIGURE 3

1/4” NPT threads

barbs

1/2” O.D. copper tube

(not furnished)

clip cut barbs

from drain fitting

compression fitting,

1/4” NPT x 1/2” O.D. tube

(not furnished)

Содержание NSC15ED

Страница 1: ...WHEN INSTALLING OPERATING AND MAINTAINING YOUR CONDITIONER OR WHEN SETTING THE TIMER CALL TOLL FREE 1 800 972 0135 IN CANADA CALL 1 800 796 6784 Designed Engineered Assembled in the U S A Systems tes...

Страница 2: ...replace the part and return it to you at no cost if our repair depart ment determines it to be defective under the terms of the warranty This warranty gives you specific legal rights and you may have...

Страница 3: ...hem in the parts bag until you are ready to use them TABLE OF CONTENTS PAGE NO WARRANTY SAFETY GUIDES 2 SPECIFICATIONS AND PERFORMANCE CLAIMS 4 BEFORE STARTING INSTALLATION 5 TYPICAL INSTALLATION ILLU...

Страница 4: ...MODEL NSC15ED RATED CAPACITY 6 600 grains with 1 4 lbs of salt 11 300 grains with 3 0 lbs of salt 15 700 grains with 8 0 lbs of salt RATED EFFICIENCY 4 680 grains lb 1 4 lbs of salt WATER USED DURING...

Страница 5: ...OTHER MATERIALS YOU WILL NEED GIn and out pipes to the softenermust be at least 3 4 size Some local codes require a minimum of 1 pipe size To plumb with 1 pipes buy adaptors to fit the 1 pipe threads...

Страница 6: ...ft Include single or 3 valve bypass INLET valve OUTLET valve BYPASS valve D for soft water SERVICE Open the inlet and outlet valves Close the bypass valve D for hard water BYPASS Close the inlet and o...

Страница 7: ...ASSEMBLY INTO INSTALLATION POSITION Be sure the installation surface is level and smooth If needed place the tank on a section of 3 4 thick min plywood Then place shims under the plywood as needed to...

Страница 8: ...end of the hose at a suitable drain point floor drain sump laundry tub etc Check and comply with local codes IMPORTANT Use high quality thick wall hose that will not easily kink or collapse The water...

Страница 9: ...let valve SLOWLY open the inlet valve pausing several times to allow the softener to pressurize slowly E After about three minutes open a HOT water faucet for one minute or until all air is expelled t...

Страница 10: ...s on pages 19 and 20 D A beeper sounds while pressing buttons for timer programming One beep signals a change in the timer display Repeated beeps means the timer will not accept a change from the butt...

Страница 11: ...nicipal supply If water contains iron add to the water hardness at a ratio of 5 grains for each 1 ppm of iron SET REGENERATION STARTING TIME NOTE RECHARGE TIME and a flashing 2 00 AM factory default s...

Страница 12: ...Any air remaining in the unit is purged to the drain 4 After the recharge has completed fully open a cold water faucet downstream from the softener and allow 50 gallons of water to pass through the sy...

Страница 13: ...to five aspirin tablets Water hardness varies greatly across the country It generally contains from 3 to 100 gpg Hard water affects living in general Hardness min erals combine with soap to make a soa...

Страница 14: ...olding metals Water without the hardness minerals soft water flows from the softener and to the house pipes After a period of time the resin beads hold all of the hardness minerals they can and cleani...

Страница 15: ...UT resin tank brine valve salt storage tank salt not shown resin bed hard water IN soft water OUT brine valve salt storage tank hard water IN hard water bypass OUT brine valve drain nozzle venturi bri...

Страница 16: ...following is the best way to check for a salt bridge Salt should be loose all the way to the bottom of the tank Take a broom handle or like tool and careful ly push it down into the salt working it up...

Страница 17: ...NG INSTALL WITH NUMBERED SIDE UP CONCAVE SIDE DOWN Cap O ring Seal Screen Support Screen Nozzle Venturi Gasket Flow Plug HVDC Nozzle Venturi Housing Screen IMPORTANT Be sure small holes in the gasket...

Страница 18: ...ation touch the same button once more VACATION NOTE North Star Demand water softeners regenerate only while water is used and softening capacity must be re stored For this reason the softener will not...

Страница 19: ...efect and check the water meter ERROR CODE DISPLAYED Err 01 Err 03 Err 04 Err 05 POSSIBLE DEFECT wiring harness or connection to switch position switch motor inop erative valve defect causing high tor...

Страница 20: ...e into each cycle and check correct switch operation CORRECT SWITCH DISPLAYS VALVE CYCLE STATUS Valve in service fill brining backwash or fast rinse position P Valve rotating from one position to anot...

Страница 21: ...ructed nozzle venturi fill flow plug brine tubing or brine valve riser pipe CAM MOTOR OUT IN POSITION MARKERS valve in service 2 After observing fill press the RECHARGE button to move the softener int...

Страница 22: ...ne OUT GND 5 WATER FLOW THROUGH VALVE SERVICE CYCLE FILL CYCLE To Valve Outlet soft water resin bed resin bed bottom distributor resin tank top distributor from Valve Inlet hard water To Valve Outlet...

Страница 23: ...plug bypass hard water to valve outlet soft water to valve outlet drain from Valve Inlet hard water from Valve Inlet hard water BRINING and BRINE RINSE CYCLES drain brine from salt stor age tank nozzl...

Страница 24: ...24 REPAIR PARTS 7 9 8 14 13 17 18 19 21 20 22 24 27 16 15 26 25 11 3 4 5 6 1 2 23 10 Valve Assembly see pages 26 27 12...

Страница 25: ...ve Assembly 12 7293395 Float Stem Guide Assembly 13 7337482 Power Supply 28V DC 14 7309358 Repl Electronic Control Board PWA KEY NO PART NO DESCRIPTION 15 7266746 Faceplate Cover order decal below z 7...

Страница 26: ...26 VALVE REPAIR PARTS 54 92 91 89 90 cross section view seal wear strip 93 66 67 88 87 86 85 84 82 83 81 77 76 75 69 65 68 64 63 62 61 60 57 56 58 59 55 53 73 74 78 79 80 50 51 52 70 71 72 70...

Страница 27: ...1 3 16 single 2 req 7336402 O ring 15 16 x 1 3 16 pack of 20 KEY NO PART NO DESCRIPTION 7113040 Turbine Support Assembly includes 1 ea of Key Nos 73 74 2 ea of Key No 72 73 Turbine Support Shaft 74 T...

Страница 28: ...S CITY STATE ZIP CODE CONDITIONER MODEL NUMBER SERIAL NUMBER DATE PURCHASED DATE PART FAILED PARTS RETURN TAG North Star 1890 Woodlane Drive Woodbury MN 55125 CUSTOMER S NAME STREET ADDRESS CITY STATE...

Отзывы: