![North Star M165955A Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/north-star/m165955a/m165955a_owners-manual_1707893026.webp)
Operation (cont’d)
26
Ground generator
Make sure the generator is grounded in accordance with instruction
given in "Installation & Initial Set-up, Step 6: Grounding the
Generator" of this manual.
WARNING: Electric shock hazard
Always ensure generator is properly grounded to prevent electrical shock.
Perform scheduled
maintenance as
needed
Make sure that any regular maintenance has been performed as
prescribed in this manual in the "Maintenance & Repair"
section.
1.
Refer to the engine owner's manual for engine maintenance
instructions.
2.
Make sure battery is charged. Charge as needed according to your
battery manufacturer's instructions.
Check/add oil
Check the oil level using the dipstick and add oil as needed.
Using a funnel, add oil up to the FULL mark on the dip stick with the
recommended oil type for your engine and expected ambient conditions.
(See engine Owner's Manual for oil type and capacity, and more detailed oil
check/fill instructions.)
WARNING: Burn hazard
Never open oil port while engine is running. Hot oil can spray over
face and body.
Notes:
o
Low oil shutdown feature prevents the generator from starting without
sufficient oil.
o
Engine is shipped without oil. You must add oil before first use.
IMPORTANT:
Under long, continuous-run operating conditions, be prepared to:
Check engine oil level every 24 operating hours if using NG/LP.
Change oil after the first 20 operating hours, and at least every 100
operating hours thereafter, or as directed in engine owner's manual.
Hook up LP/NG
supply
Propane (LP)
:
1)
Make sure the fuel hose is securely connected to the propane tank
regulator on one end, and the 1/2” NPT gas inlet on the regulator
assembly kit.
2)
Open the propane tank main valve.
3)
Check 1/2” NPT gas inlet connection for leaks each time you connect.
Use the leak test method described below.
Natural Gas:
1)
Make sure the gas line is securely connected to the 1/2” NPT gas inlet on
the regulator assembly kit.
2)
Open line valve, if gas line is so equipped.
3)
Check 1/2” NPT gas inlet connection for leaks each time you connect.
Use the leak test method described below.
Содержание M165955A
Страница 2: ...Hazard Signal Word Definitions 2...
Страница 39: ...Generator Exploded View Rev A 39...
Страница 42: ...Generator Head Exploded View Rev A 42...
Страница 45: ...45 This page left intentionally blank...
Страница 46: ...46 Assembled by Northern Tool Equipment Company Inc Burnsville MN 55306 NorthernTool com...