Summary of Important Safety Information for Operation 

 

                      

33

 

                             

 

 

This section provides a summary of the various safety procedures and measures that have been 

presented throughout the manual.  Keep this summary handy and refer to it to refresh your 

memory about how to safely use your generator. 

 

   WARNING 

 

Carefully read and make sure you understand the following safety information before using 
the generator.  Improper use or maintenance of the generator can result in 

serious injury or 

death 

from 

carbon monoxide poisoning, electric shock, fire/explosion, or burns

 

 

General 

• 

Read manual.

  Read this Owner’s Manual and the engine Owner’s Manual completely before attempting to 

set-up and use the generator

.  

Serious injury or death can result if safety instructions are not followed. 

• 

Instruct operators

. The generator owner must instruct all operators in safe generator set-up and operation.  

Do not allow anyone to operate the generator who has not read the Owner’s Manual and been instructed on its 
safe use.  

• 

Adults only.

  Only trained adults should set up and operate the generator.  Do not let children operate. 

• 

Under the influence

.  Never operate, or let anyone else operate, the generator while under the influence of 

alcohol, drugs, or medication. 

• 

Intended use

.  Carefully read about and understand the intended use of this generator. Do not use for other 

purposes, as unforeseen hazards or equipment damage may result. 

 

Prohibition Against Modifications 

Never modify or alter the generator in any way.  Modifications can create serious safety hazards and will also 
void the warranty.  

• 

Engine speed

. Never attempt to modify the engine speed setting. The engine speed is preset at 3600 RPM for 

safe and optimal performance of the generator.  If speed needs adjusting, it must be done by factory-
authorized personnel.  

• 

Fuel/exhaust system

.  Never modify the exhaust system, fuel tanks, or fuel lines.  Carbon monoxide 

poisoning, fire, or explosion could result.  

• 

Guards

.  Do not operate generator unless all guards and cover shields, which prevent access to moving parts 

and pinch points, are in place.  Failure to guard the power transmission mechanisms

 may result in serious 

injury or death.

 

 

Safety – Installation & Set-up 

 
 

Installation / Initial Set-up Safety 

• 

Dry, level surface

. Situate generator on a dry, firm, level surface.  Ensure generator sits level and will not 

slide or shift during operation.  Block wheels if applicable. 

• 

Operate OUTSIDE only – dangerous carbon monoxide exhaust

!  Generators give off carbon monoxide 

exhaust, a poisonous gas that can kill.  You CANNOT smell it, see it, or taste it.  ONLY run generator 
OUTDOORS and away from building air intakes.  NEVER run generator inside homes, garages, sheds, or 
other semi-enclosed spaces.  These spaces can trap poisonous gases, EVEN if you run a fan or open windows.  
Carbon monoxide is given off whether you are using gasoline, natural gas, or propane to power the generator. 

• 

No vehicle/marine use.

  This generator is NOT designed or approved for use in vehicles or marine 

applications.  Never run the generator inside RVs or other vehicles, on boats, or on pick-up truck beds. 

• 

Cooling ventilation

.  The generator needs adequate, unobstructed flow of air to allow for proper cooling of 

engine and generator head.  Situate so there is adequate clearance around generator to allow for cooling 
airflow.  Do not allow debris to accumulate and block airflow. 

• 

Grounding

.  Always ensure generator is properly grounded to prevent electrical shock.  This generator is 

equipped with a grounding post.  Always complete the grounding path from the generator to a copper pipe/rod 
driven into moist earth to a sufficient depth.  Check with an electrician for local grounding requirements.  If a 

Содержание M165911V

Страница 1: ...cords of proper size NEVER plug the generator directly into a wall outlet ANY connection to a building s electrical system MUST ISOLATE THE GENERATOR FROM UTILITY POWER via a UL approved transfer swit...

Страница 2: ...Hazard Signal Word Definitions 2...

Страница 3: ...ILDING BACK UP or PORTABLE Power Source 13 4 Selecting a Suitable Site 16 5 Grounding the Generator 18 Operation 1 General Safety Rules for Operation 19 2 Preparing for Operation 22 3 Starting the Eng...

Страница 4: ...electrical devices and may also result in fire Be sure to read about site selection and grounding requirements for running this generator More detailed information can be found in the Installation In...

Страница 5: ...questions about the appropriate use of this generator Warranty Registration Please fill out and submit the warranty registration card so that we have your contact information for any future product l...

Страница 6: ...798 RPM Fuel Type Non leaded automobile gasoline Fuel Capacity 6 5 gallons 24 6 L Oil Capacity 1 16 US quarts 1 1 L Starting Method Recoil 120 V Receptacle 20 Amp A duplex NEMA 5 20R 120 240 V Recepta...

Страница 7: ...e electric start engine Extend run 6 5 gallon fuel tank Maintenance free brushless alternator design Smooth running focus mount isolation system Always make sure safety labels are in place and in good...

Страница 8: ...uit Breakers 8 Gas Cap with Gauge 2 120 240V 20A Locking Receptacle 9 6 5 Gal Gas Tank 3 120V 20A Duplex Receptacle 10 Generator Head 4 Oil Drain Plug 11 Vibration Isolation Mount 5 Engine On Off Swit...

Страница 9: ...locate this switch and be familiar with its location before operating the generator Reference 6 Air Cleaner Refer to your Honda engine manual for air cleaner care Reference 7 Super Silent Muffler 3 dB...

Страница 10: ...a device s nameplate If wattage is not given on the device s nameplate the wattage may be calculated by multiplying the nameplate voltage by nameplate amperage Watts Volts X Amps Example conversion t...

Страница 11: ...you will be powering at the same time with the generator 2 List the greater of the running or starting wattage next to each device as obtained from the devices nameplate or Table 1 If only the running...

Страница 12: ...ing Each of these steps is discussed in detail below 1 Unpacking Delivery Inspection You should inspect the generator immediately after you receive delivery See the Machine Component Identification se...

Страница 13: ...r building s electrical system by isolating your generator from your utility company s power lines AND b Connects your generator to a critical subset of your building s circuits that are needed for em...

Страница 14: ...ce you can plug electric devices and appliances directly into the generator s electrical outlets There are two different kinds of electrical outlets on the generator 1 One 120 240 Volt 20 Amp locking...

Страница 15: ...ire or damage to connected devices All extension and appliance cords must be in good condition and not worn bare frayed or otherwise damaged WARNING Use of damaged electric cords can cause electric sh...

Страница 16: ...propane as the fuel source to power the generator Follow the directions below for choosing a location to operate your generator in order to avoid carbon monoxide poisoning The location you choose to...

Страница 17: ...at least 7 from exhaust and allow for adequate clearance above generator so that heat does not build up Hot exhaust clearance The exhaust gas from your generator is extremely hot and can cause combust...

Страница 18: ...he pipe 3 Run a 10 gauge wire from the clamp to the generator grounding post located on the electrical panel 4 Do not connect the generator grounding post to a water pipe or a ground used by a radio s...

Страница 19: ...adults should set up and operate the generator Do not let children operate Intended use Carefully read about and understand the intended use of this generator Do not use for other purposes as unforese...

Страница 20: ...ate of California to cause cancer birth defects or other reproductive harm Avoid inhalation of exhaust Wet conditions Do not operate the generator or handle any electrical equipment while standing in...

Страница 21: ...d retain static electric charge as can objects made of conductive material e g metal water if they are not electrically grounded The static electric charge on an object such as a human body or plastic...

Страница 22: ...ical shock Perform scheduled maintenance as needed Make sure that any regular maintenance has been performed as prescribed in this manual in the Maintenance Repair section Refer to the engine owner s...

Страница 23: ...e 2 Turn generator engine off and allow to cool for at least two minutes before removing gas cap Note A running or still hot engine is hot enough to ignite fuel 3 Remove generator gasoline cap 4 Add g...

Страница 24: ...el the engine on a regular basis A tank of gasoline should last about 4 hours under 100 load and about 8 hours under 50 load Inspect Fuel System Check for Leaks Inspect fuel system check for leaks BEF...

Страница 25: ...y Allow starter cord to return slowly 5 When engine starts move choke lever to RUN position 6 Under long continuous run operating conditions be prepared to a Check and refuel the engine on a regular b...

Страница 26: ...3 Measured voltage should be within the following ranges a 120V 10 at 120V receptacles b 240V 10 at 240V receptacles 4 If measured voltage is not within the specified range have generator adjusted by...

Страница 27: ...e recommended sequence is as follows a Connect items with motors such as refrigerators freezers air conditioners or small hand tools one at a time Let each motor stabilize before connecting the next d...

Страница 28: ...m sources of heat open flames sparks or pilot lights even if the generator s fuel tank is empty Residual fuel in the tank could ignite o Away from extreme high or low temperatures Prevent accidental s...

Страница 29: ...ding fuel stabilizer to the gasoline following manufacturer s instructions Fuel stabilizer steps 1 Ensure gasoline tank is full 2 Add fuel stabilizer to fuel tank 3 Run engine at least 10 minutes afte...

Страница 30: ...ging the capacitor Replace guards Make sure all guards and shields are replaced after servicing the generator Repair Major service including the installation or replacement of parts should be performe...

Страница 31: ...ons Replace if damaged Keep generator clean Keep generator clean If dust or debris accumulates on the generator clean the generator with a damp cloth or soft bristle brush Do not allow air intakes to...

Страница 32: ...or overheating a Generator is overloaded b Insufficient ventilation a Reduce the load See Power Load Planning Mgt section of this manual b Make sure there is at least 7 feet of clearance on all sides...

Страница 33: ...djusting it must be done by factory authorized personnel Fuel exhaust system Never modify the exhaust system fuel tanks or fuel lines Carbon monoxide poisoning fire or explosion could result Guards Do...

Страница 34: ...s may result in serious injury or death Know how to operate Be thoroughly familiar with all controls and with the proper use of the equipment Know how to stop the generator quickly if needed Personal...

Страница 35: ...r for any voltage sensitive electronic equipment you will be powering with the generator Wet conditions Do not operate the generator or handle any electrical equipment while standing in water while ba...

Страница 36: ...accumulates in the windings If generator cannot be exercised on a regular basis prepare generator for long term storage Periodic maintenance Perform periodic maintenance as directed in this manual to...

Страница 37: ...Generator Exploded View Rev V 37...

Страница 38: ...Honda Engine 1 11 778529 Generator 1 12 306459 Engine Ground Wire 1 13 777302 Generator Bracket 1 14 38184 Engine Cover 1 15 34172 Isolation Mount 4 16 32844 Bottom Bracket 4 17 778480 Generator Base...

Страница 39: ...6446 Locking Receptacle 20 Amp 120 240 Volt NEMA L14 20R 1 4 306429 Grounding Post 1 5 31085 Thermal Circuit Breaker 2 6 38191 Wire Harness 1 7 82004 8 32 X Button Head Cap Screw 4 8 82005 8 32 Nut 4...

Страница 40: ...53 Fan 1 4 306406 Drive End Bracket 1 5 778954 Enclosing Band 1 6 305554 End Cover 1 7 306408 End Cover Plug 1 8 778955 Stator 1 9 778956 Rotor 1 10 778959 Diode 2 11 778957 Securing Stud 1 12 307485...

Страница 41: ...h as engines are guaranteed by their manufacturer and can be serviced at factory authorized locations near you Any costs incurred due to replacement or repair of items outside of a NorthStar approved...

Страница 42: ...42 Manufactured by Northern Tool Equipment Co 2800 SouthCross Drive West P O Box 1499 Burnsville MN 55337 0499...

Отзывы: