North Star M165911V Скачать руководство пользователя страница 29

Operation (cont’d) 

 

 

 

29

Prepare engine for 
long term storage if 
needed 

If you will not be able to exercise the generator regularly, you must 
prepare the engine for long term storage 

to prevent gum deposits from 

forming and causing malfunction of the engine.

 

 

Prepare engine for long term storage by: 

 

Removing all gasoline

 from the tank and carburetor 

OR 

Adding fuel stabilizer

 to the gasoline (following manufacturer’s 

instructions) 

Fuel stabilizer steps: 

1.  Ensure gasoline tank is full. 
2.  Add fuel stabilizer to fuel tank. 
3.  Run engine at least 10 minutes after adding stabilizer to allow it to 

enter the fuel system. 

4.  Shut off engine 
5.  Disconnect spark plug wire and remove spark plug 
6.  Add one teaspoon oil through spark plug hole 
7.  Place rag over spark plug hole and turn starter (or pull the recoil) a 

few times to lubricate the combustion chamber. 

8.  Replace spark plug, but do not reconnect the spark plug wire. 

 

 

Содержание M165911V

Страница 1: ...cords of proper size NEVER plug the generator directly into a wall outlet ANY connection to a building s electrical system MUST ISOLATE THE GENERATOR FROM UTILITY POWER via a UL approved transfer swit...

Страница 2: ...Hazard Signal Word Definitions 2...

Страница 3: ...ILDING BACK UP or PORTABLE Power Source 13 4 Selecting a Suitable Site 16 5 Grounding the Generator 18 Operation 1 General Safety Rules for Operation 19 2 Preparing for Operation 22 3 Starting the Eng...

Страница 4: ...electrical devices and may also result in fire Be sure to read about site selection and grounding requirements for running this generator More detailed information can be found in the Installation In...

Страница 5: ...questions about the appropriate use of this generator Warranty Registration Please fill out and submit the warranty registration card so that we have your contact information for any future product l...

Страница 6: ...798 RPM Fuel Type Non leaded automobile gasoline Fuel Capacity 6 5 gallons 24 6 L Oil Capacity 1 16 US quarts 1 1 L Starting Method Recoil 120 V Receptacle 20 Amp A duplex NEMA 5 20R 120 240 V Recepta...

Страница 7: ...e electric start engine Extend run 6 5 gallon fuel tank Maintenance free brushless alternator design Smooth running focus mount isolation system Always make sure safety labels are in place and in good...

Страница 8: ...uit Breakers 8 Gas Cap with Gauge 2 120 240V 20A Locking Receptacle 9 6 5 Gal Gas Tank 3 120V 20A Duplex Receptacle 10 Generator Head 4 Oil Drain Plug 11 Vibration Isolation Mount 5 Engine On Off Swit...

Страница 9: ...locate this switch and be familiar with its location before operating the generator Reference 6 Air Cleaner Refer to your Honda engine manual for air cleaner care Reference 7 Super Silent Muffler 3 dB...

Страница 10: ...a device s nameplate If wattage is not given on the device s nameplate the wattage may be calculated by multiplying the nameplate voltage by nameplate amperage Watts Volts X Amps Example conversion t...

Страница 11: ...you will be powering at the same time with the generator 2 List the greater of the running or starting wattage next to each device as obtained from the devices nameplate or Table 1 If only the running...

Страница 12: ...ing Each of these steps is discussed in detail below 1 Unpacking Delivery Inspection You should inspect the generator immediately after you receive delivery See the Machine Component Identification se...

Страница 13: ...r building s electrical system by isolating your generator from your utility company s power lines AND b Connects your generator to a critical subset of your building s circuits that are needed for em...

Страница 14: ...ce you can plug electric devices and appliances directly into the generator s electrical outlets There are two different kinds of electrical outlets on the generator 1 One 120 240 Volt 20 Amp locking...

Страница 15: ...ire or damage to connected devices All extension and appliance cords must be in good condition and not worn bare frayed or otherwise damaged WARNING Use of damaged electric cords can cause electric sh...

Страница 16: ...propane as the fuel source to power the generator Follow the directions below for choosing a location to operate your generator in order to avoid carbon monoxide poisoning The location you choose to...

Страница 17: ...at least 7 from exhaust and allow for adequate clearance above generator so that heat does not build up Hot exhaust clearance The exhaust gas from your generator is extremely hot and can cause combust...

Страница 18: ...he pipe 3 Run a 10 gauge wire from the clamp to the generator grounding post located on the electrical panel 4 Do not connect the generator grounding post to a water pipe or a ground used by a radio s...

Страница 19: ...adults should set up and operate the generator Do not let children operate Intended use Carefully read about and understand the intended use of this generator Do not use for other purposes as unforese...

Страница 20: ...ate of California to cause cancer birth defects or other reproductive harm Avoid inhalation of exhaust Wet conditions Do not operate the generator or handle any electrical equipment while standing in...

Страница 21: ...d retain static electric charge as can objects made of conductive material e g metal water if they are not electrically grounded The static electric charge on an object such as a human body or plastic...

Страница 22: ...ical shock Perform scheduled maintenance as needed Make sure that any regular maintenance has been performed as prescribed in this manual in the Maintenance Repair section Refer to the engine owner s...

Страница 23: ...e 2 Turn generator engine off and allow to cool for at least two minutes before removing gas cap Note A running or still hot engine is hot enough to ignite fuel 3 Remove generator gasoline cap 4 Add g...

Страница 24: ...el the engine on a regular basis A tank of gasoline should last about 4 hours under 100 load and about 8 hours under 50 load Inspect Fuel System Check for Leaks Inspect fuel system check for leaks BEF...

Страница 25: ...y Allow starter cord to return slowly 5 When engine starts move choke lever to RUN position 6 Under long continuous run operating conditions be prepared to a Check and refuel the engine on a regular b...

Страница 26: ...3 Measured voltage should be within the following ranges a 120V 10 at 120V receptacles b 240V 10 at 240V receptacles 4 If measured voltage is not within the specified range have generator adjusted by...

Страница 27: ...e recommended sequence is as follows a Connect items with motors such as refrigerators freezers air conditioners or small hand tools one at a time Let each motor stabilize before connecting the next d...

Страница 28: ...m sources of heat open flames sparks or pilot lights even if the generator s fuel tank is empty Residual fuel in the tank could ignite o Away from extreme high or low temperatures Prevent accidental s...

Страница 29: ...ding fuel stabilizer to the gasoline following manufacturer s instructions Fuel stabilizer steps 1 Ensure gasoline tank is full 2 Add fuel stabilizer to fuel tank 3 Run engine at least 10 minutes afte...

Страница 30: ...ging the capacitor Replace guards Make sure all guards and shields are replaced after servicing the generator Repair Major service including the installation or replacement of parts should be performe...

Страница 31: ...ons Replace if damaged Keep generator clean Keep generator clean If dust or debris accumulates on the generator clean the generator with a damp cloth or soft bristle brush Do not allow air intakes to...

Страница 32: ...or overheating a Generator is overloaded b Insufficient ventilation a Reduce the load See Power Load Planning Mgt section of this manual b Make sure there is at least 7 feet of clearance on all sides...

Страница 33: ...djusting it must be done by factory authorized personnel Fuel exhaust system Never modify the exhaust system fuel tanks or fuel lines Carbon monoxide poisoning fire or explosion could result Guards Do...

Страница 34: ...s may result in serious injury or death Know how to operate Be thoroughly familiar with all controls and with the proper use of the equipment Know how to stop the generator quickly if needed Personal...

Страница 35: ...r for any voltage sensitive electronic equipment you will be powering with the generator Wet conditions Do not operate the generator or handle any electrical equipment while standing in water while ba...

Страница 36: ...accumulates in the windings If generator cannot be exercised on a regular basis prepare generator for long term storage Periodic maintenance Perform periodic maintenance as directed in this manual to...

Страница 37: ...Generator Exploded View Rev V 37...

Страница 38: ...Honda Engine 1 11 778529 Generator 1 12 306459 Engine Ground Wire 1 13 777302 Generator Bracket 1 14 38184 Engine Cover 1 15 34172 Isolation Mount 4 16 32844 Bottom Bracket 4 17 778480 Generator Base...

Страница 39: ...6446 Locking Receptacle 20 Amp 120 240 Volt NEMA L14 20R 1 4 306429 Grounding Post 1 5 31085 Thermal Circuit Breaker 2 6 38191 Wire Harness 1 7 82004 8 32 X Button Head Cap Screw 4 8 82005 8 32 Nut 4...

Страница 40: ...53 Fan 1 4 306406 Drive End Bracket 1 5 778954 Enclosing Band 1 6 305554 End Cover 1 7 306408 End Cover Plug 1 8 778955 Stator 1 9 778956 Rotor 1 10 778959 Diode 2 11 778957 Securing Stud 1 12 307485...

Страница 41: ...h as engines are guaranteed by their manufacturer and can be serviced at factory authorized locations near you Any costs incurred due to replacement or repair of items outside of a NorthStar approved...

Страница 42: ...42 Manufactured by Northern Tool Equipment Co 2800 SouthCross Drive West P O Box 1499 Burnsville MN 55337 0499...

Отзывы: