Troubleshooting
32
TROUBLESHOOTING
Problem
Possible Causes
Possible Remedies
Engine will not start.
a) Low oil level.
b) Fouled spark plug.
c) Out of fuel.
d) Stop switch in OFF position.
a) Fill crankcase to proper oil
level.
b) Clean or replace spark plug.
c) Fill fuel tank.
d) Place switch in ON position.
Voltage too low.
a) Engine speed too slow.
b) Generator is overloaded.
a) Bring generator to a qualified
technician for adjustment.
b) Reduce the load. (See Power
Load Planning & Mgt. section
of this manual.)
Circuit breaker trips.
a) Defective load connected to generator.
b) Defective receptacle.
c) Generator overloaded.
a) Disconnect load.
b) Replace receptacle.
c) Reduce the load. (See Power
Load Planning & Mgt. section
of this manual.)
Voltage too high.
a) Engine speed too high.
a) Bring generator to a qualified
technician for adjustment.
Generator overheating. a) Generator is overloaded.
b) Insufficient ventilation.
a) Reduce the load. (See Power
Load Planning & Mgt. section
of this manual.)
b) Make sure there is at least 3
feet of clearance on all sides
of generator.
No output voltage.
a) Defective load connected to generator.
b) Broken or loose wire.
c) Defective receptacle.
d) Defective stator.
e) Defective rotor.
f) Defective capacitor.
g) Circuit breaker tripped.
a) Disconnect load.
b) Bring generator to a qualified
technician for repair.
c) Replace receptacle.
d) Bring generator to a qualified
technician for repair.
e) Bring generator to a qualified
technician for repair.
f) Bring generator to a qualified
technician for repair.
g) Reset circuit breaker and
reduce loads connected to the
generator.
Engine lacks power.
a) Generator is overloaded.
b) Dirty air filter.
a) Reduce the load. (See Power
Load Planning & Mgt. section
of this manual.)
b) Clean or replace air filter.
Engine shuts down
during operation.
a) Out of fuel.
b) Low oil level.
a) Fill fuel tank.
b) Fill crankcase to proper oil
level.