32
Troubleshooting
Pressure Washer Will Not Run At All - No Power
Causes
Solutions
Machine turned OFF
Turn Pump switch ON
Line circuit breaker tripped
Check for tripped circuit breaker in building
Circuit Breaker Trips
Causes
Solutions
Voltage too low
Check the voltage
Circuit Breaker Overloaded
Make sure there is no other equipment using the same circuit.
Pressure set too high
Check/adjust pressure setting on unloader.
Pressure Washer Runs but
Burner Doesn’t FIre
Causes
Solutions
Air
Air intake is blocked or restricted
Inspect & remove any blockages
Air leaking
Inspect rubber boot and connections between the heat exchanger and blower for
leaks. Replace boot or tighten connections
Improper air adjustment
See Burner adjustment section of manual
Fuel
Fuel tank empty
Fill fuel tank with diesel.
Fuel filter water separator is clogged or full of
water
Drain or replace if needed
Clogged fuel nozzle
Replace
Fuel pump malfunctioning
Fuel solenoid, coupler, or pump itself may need to be replaced. Contact product
support.
Check fuel pressure and replace if needed
Ignition
Electrodes damaged or worn
Clean, adjust, or replace electrodes. See maintenance and repair section of manual.
Ignition coil failure or improperly gapped
see maintenance and repair section or contact product support
Other
Heat switch turned OFF
Turn heat switch ON.
Thermostat set too low or off
Set thermostat to desired temp (if equipped).
Trigger gun is not open
Open Trigger gun to allow flow
Flow switch failed or clogged
Clean or replace flow switch. See Maintenance and repair section of manual
Primary control board malfunctioning
Call Product Support.
Flame sensor
Call Product Support
Low Pressure
Causes
Solutions
Low water flow
Make sure the water supply is more than 4 gpm
Partially clogged or damaged nozzle
Clean or replace nozzle
Smoke from Heat Exchanger
Causes
Solutions
Air band not adjusted properly
Adjust the air band until the burner burns cleanly. See installation Instructions.
Poor quality fuel
Use kerosene for the cleanest burn.