North Star 13000 PTOG Скачать руководство пользователя страница 6

5

Reference 17 - Breather/Oil Fill Plug.   

Use

SAE 90 gear oil.  Maintain the  correct  oil  level.
Over filling can cause the oil to over heat and
damage seals and bearings.  The gear box is
shipped with temperary plastic  plug,  remove  and
replace with the metal breather plug that is  in  the
manual bag.

INTRODUCTION

Before attempting to mount your  generator,

thoroughly study the instructions and cautions in this
manual to assure you are fully  acquainted  with  the
operation of all components of this generator. Proper
preparation, operation and maintenance will result
in operator safety, best performance and long life of
the generator.  NorthStar is constantly  improving  its
products.  The specifications outlined herein are
subject to change without prior notice or obligation.
The purchaser and/or user assumes liability of any
modification and/or alterations on this  equipment
from original design and manufacture.  Before using,
the user shall determine the suitability of this product
for its intended use and assumes liability therein.

RULES FOR SAFE OPERATIONS

Safety precautions are essential when operating

this generator. Respectful and cautious operation
will considerably lessen the possibilities of  a
personal injury.  This manual  will warn of specific
personal injury potential, and these will be
designated by the symbol:

                      

 

WARNING

  This generator is equipped

with a grounding screw, located on the generator
frame for your protection.  Always complete  the
grounding path from the generator to a copper
pipe/rod that is driven into  moist  earth,  to  prevent
electrical shock.

ALWAYS

 use electrical cords that are in good

condition.  Worn, bare,  frayed  or  otherwise
damaged cords can cause electric shock.

ALWAYS

 use a ground fault circuit interrupter

(GFCI) in damp or  highly  electrical  conductive
areas and on construction job sites to prevent
electric shock.

ALWAYS

 remove PTO driveline before working

on the generator.

ALWAYS 

provide adequate ventilation. Do  not

operate generator in any enclosed  or  narrow  space.
Engines consume oxygen and give off deadly
carbon monoxide, a poisonous gas.  Improper
ventilation will cause damage to generator and
possible injury to people.

ALWAYS

 

remove all oil or gasoline deposits

and accumulated dirt from generator and
immediate area.  Keep generator head  and  engine
clean.

ALWAYS

 

wear ear protection while operating

generator.

ALWAYS

 

keep area around generator clean.

NEVER

 operate the generator without proper

guarding.

NEVER

 operate the generator continuously

when PTO driveline is at angle greater  than  15

°

both horizontally and vertically .

NEVER

 operate the generator  while  wearing

loose fitting clothing such as neckties, scarves or
untucked shirts.

NEVER

 operate the generator, or  handle  any

electrical equipment while standing in water, while
barefoot, while hands are wet or while in the  rain  or
snow.  Electric shock may result.

NEVER

 operate the generator  under  the

following conditions:

A. Excessive change in engine speed, slow 

or  fast.

B. Overheating in load connecting devices.
C. Sparking or arcs from generator.
D.  Loss of electrical output.
E. Damaged receptacles.
F. Engine misfire.
G. Excessive vibration.
H. Enclosed compartments, or confined areas.
I.  Flame or smoke.
J. Rain, snow or wet conditions.
K. Operator non-attendance.
L.  Without proper guarding in place.

 

WARNING

  Keep fire extinguisher close

by your generator  and be familiar with how to use
it.  Consult your local  fire  department  for  correct
extinguisher type.

 

DANGER

  Remember, exhaust fumes are

deadly carbon monoxide, a poisonous gas and
must be vented to the outside  where  there  are  no
people.  Cooling air of sufficient amounts must  be
brought in and exhausted out to ensure proper
cooling of the engine and generator.

INSTALLATION

Содержание 13000 PTOG

Страница 1: ...DEL 13000 PTOG ITEM 165929 Power Take Off Generator M165929A OWNER S MANUAL 13000 PTOG Any Questions Comments or Problems Call Customer Service at 1 800 270 0810 Hours Monday Friday 7 30 AM to 5 30 PM...

Страница 2: ...Generator IMPORTANT If this machine is used by anyone who is not the owner or is loaned or rented make certain the operator Is instructed in safe and proper operation of this machine Reads and underst...

Страница 3: ...40 Amp A thermal push to reset style Gear Box Gear Ratio 1 7 Gear Oil SAE 80W 90 Oil Capacity 86 Qt 82 L Dimensions Length 28 38 72 1 cm Width 14 25 36 2 cm Height 12 50 31 1 cm Gross Weight 127 lb 57...

Страница 4: ...0A Circuit Breaker 11 Shield 3 20A Circuit Breakers 12 Gear Box 4 Warning Decals 13 Grounding Screw 5 1 3 8 6 Spline Input Shaft 14 Mounting Holes 6 Oil Drain Plug 15 Fan Vents 7 Voltmeter 16 Oil Leve...

Страница 5: ...EMA plug number L5 30P which is supplied with the generator Reference 10 120 240V Receptacle This straight blade receptacle is 120 240V 50A This receptacle accepts a NEMA plug number 14 50P ALWAYS use...

Страница 6: ...r highly electrical conductive areas and on construction job sites to prevent electric shock ALWAYS remove PTO driveline before working on the generator ALWAYS provide adequate ventilation Do not oper...

Страница 7: ...oncrete After the the generator is firmly mounted attach the PTO driveline to the generator then the tractor Use a synchronized PTO driveline rated at 24 HP minimum DANGER Always have proper guarding...

Страница 8: ...tors particularly low cost split phase motors are very hard to start and require 5 to 7 times more current to start than to run Capacitor motors are easier to start and usually require 2 to 4 times as...

Страница 9: ...Compressor 1 2 HP 1400 a Curling Iron 700 Dishwasher 1200 Edge Trimmer 500 Electric Nail Gun 1200 Electric Range one element 1500 Electric Skillet 1250 Freezer 800 b Furnace Fan 1 3 HP 1200 a Hair Dry...

Страница 10: ...ch or a stop watch the clock should be correct within 2 seconds per minute All speed setting adjustments should be done by a qualified technician GENERATOR CARE The generator head is a two pole 3600 R...

Страница 11: ...loose wire c Defective receptacle d Defective stator e Defective rotor f Defective capacitor g Defective circuit breaker h Engine speed too slow I PTO not engaged j Gear box is malfunctioning a Disco...

Отзывы: