ALWAYS

 remove the spark plug or spark plug

wire before working on the engine or generator, this
prevents accidental starting.

ALWAYS 

provide adequate ventilation. Do not

operate generator  in any enclosed or  narrow  space.
Engines consume oxygen and give off deadly  carbon
monoxide, a poisonous gas.  Improper ventilation  will
cause damage to generator and possible injury to
people.

ALWAYS

 

remove all oil or gasoline deposits and

accumulated dirt from generator and immediate area.
Keep generator head and engine clean.

NEVER

 operate the generator  under  the  following

conditions:

A. Excessive change in engine speed, slow  or

fast.

B. Overheating in load  connecting devices.
C. Sparking or arcs from generator.
D.  Loss of electrical output.
E. Damaged receptacles.
F. Engine misfire.
G. Excessive vibration.
H. Enclosed compartments, or confined 

areas.

I. Flame 

or smoke.

J. Rain, snow or wet conditions.
K. Operator non-attendance.
L.  Without proper guarding in place.

 

WARNING

  Keep fire  extinguisher  close

by your generator  and be familiar with how to use it.
Consult your local fire department  for  correct
extinguisher type.

             INSTALLATION

OUTDOORS:  

Choose a location where the

generator  will not be exposed to rain, snow or direct
sunlight.  Position the generator on secure, level
ground so it will not tip or  slide down  a hill.   Place  the
generator so that the
exhaust fumes will not be
directed towards people.

The installation  site

must be free from water,
moisture, or dust.   All
electrical components
should be  protected from
excessive moisture or
the insulation system will
deteriorate and  result  in
grounding or shorting out of the generating system.

Foreign matters, such as dust, dirt, sand, lint or

abrasive materials can cause damage to the  generator
head and engine if allowed into the cooling system.

POWER TRANSMISSION:  

The recommended

method to transfer the power from  the  engine  to  the
generator is by using sheaves (pulleys) and a  V-belt.

The generator shaft is 28 mm  diameter  X 2.38” long
with a 8mm key way.  The  table below  shows  the
recommended horsepower and  sheaves  .

The shaft speed of the generator must be between

3480-3780 RPM.  At no load the correct speed is  3780
RPM.  If the engine is a 3750 RPM engine, then a

sheave diameter ratio of 1:1 should be used.   This
means that the diameter of the sheave on the engine
is the same as the diameter of  the  sheave  on  the
generator.  If smaller than recommended sheaves are
used, the life of the belt will be shortened.  The
possibility of belt slippage also increases with a
smaller sheave.

The engine and generator should be mounted to a

plate or surface that can withstand the constant
vibration and stresses that will be produced.  See
figure 3 for a possible mounting configuration.

   

Figure 3

NOTE:  Guards are removed to show  details

 

DANGER

  Always have proper  guarding

of the V-belt(s) and sheaves to prevent access to any
pinch points.  Failure to guard the power transmission
mechanisms may result in serious injury or death.

The user  shall determine  the proper  belt

tensioning method for their specific use.

To determine belt tension:

Measure

 L

 - the center to center distance of the two

sheaves.
Measure

 d

 - the deflection of the belt.

Engine Hp

Double Sheave Dia.

V-Belt Type

Quantity

Double Sheave Dia.

V-Belt Type

Quantity

18 Hp

6.60”

B Belt

2

6.00”

3VX Belt

2

Foot print  of
mounting feet
is shown at left.
Use 7/16”
grade 5 bolts.

00292

00307

00039

Optional mount kit (item #165935) is available in
the Northern catalog and the NorthStar parts
catalog.  Includes 2 plates and mounting hardware.

00291

Содержание 10000 BDG

Страница 1: ...00 BDG ITEM 165928 Belt Driven Generator M165928A OWNER S MANUAL 10000 BDG Any Questions Comments or Problems Call Customer Service at 1 800 270 0810 Hours Monday Friday 7 30 AM to 5 30 PM Saturday 7...

Страница 2: ...n Generator IMPORTANT If this machine is used by anyone who is not the owner or is loaned or rented make certain the operator Is instructed in the safe and proper operation of this machine Reads and u...

Страница 3: ...e Speed 3480 3780 RPM 120V Receptacle 2 20 Amp A duplex NEMA 5 20R 30 Amp A twistlock NEMA L5 30R 120 240V Receptacle 50 Amp A Straight blade NEMA 14 50R Circuit Breaker 2 20 Amp A thermal push to res...

Страница 4: ...Circuit Breakers 7 120 240V 50A Receptacle 2 30A Circuit Breaker 8 28 mm shaft 3 20A Circuit Breakers 9 Grounding screw 4 Voltmeter 10 Mounting feet 5 120V 20A Duplex Receptacles 11 Fan vents 6 120V...

Страница 5: ...o mount your generator thoroughly study the instructions and cautions in this manual to assure you are fully acquainted with the operation of all components of this generator Proper preparation operat...

Страница 6: ...t sand lint or abrasive materials can cause damage to the generator head and engine if allowed into the cooling system POWER TRANSMISSION The recommended method to transfer the power from the engine t...

Страница 7: ...he wattage listed on the equipment nameplate is its rated output However some equipment may require three to ten times more wattage than its rating on the nameplate as the wattage is influenced by the...

Страница 8: ...2000 15 CAUTION Equipment damage can result from the low voltage caused by using an extension cord with a small wire size Use this chart to estimate the total load on your generator For Determining Ge...

Страница 9: ...a stop watch the clock should be correct within 2 seconds per minute All speed setting adjustments should be done by a qualified technician GENERATOR CARE The generator head is a two pole 3600 RPM 60...

Страница 10: ...erator overheating a Generator is overloaded b Insufficient ventilation a Reduce the load See Load Application section of this manual b Make sure there is at least 3 feet of clearance on all sides of...