D/S One/Two Channel (Modules 1*, 2*, 3*, 4*)
75DS2 Operations Manual
North Atlantic Industries, Inc.
11/11/2011
Rev: 2011-11-11-1000
www.naii.com
Page 11 of 43
Wrap S/D Angle (Read)
The Wrap S/D Angle reads back the actual output signal (angle), which is used to verify that the actual output is
set to commanded angle. Read individual channels 1 or 2.
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
Wrap S/D Data (
) Hi
180
90
45
22.5
11.25 5.625 2.813 1.406 .703
.352
.176
.088
.044
.022
.011
.0055
Wrap S/D Data (
) Lo
.00274 .00137 .00068 .00034 .00017 .00008 .00004 .00002
X
X
X
X
X
X
X
X
Measured Reference Voltage
Each individual
channel input signal voltage “V
REF
” is measured and the value reported to a corresponding read
register. The input voltage is reported to a resolution of 10 mv rms. The output is in integer decimal format.
For
example
, if channel 1 input REF voltage is 26.0 V
RMS
, the output measurement word from the corresponding
register would be 2600.
Measured Signal Voltage
Each individual channel input signal voltage “V
L-L
” is measured and the value reported to a corresponding read
register. The input voltage is reported to a resolution of 10 mv rms. The output is in integer decimal format.
For
example
, if channel 1 input signal voltage is 11.8 V
RMS
, the output measurement word from the corresponding
register would be 1180.
Signal Loss Threshold
Each individual channel input signal voltage “V
L-L
” is measured and the value reported to a corresponding read
register. The signal loss detection circuitry can be tailored to report a signal loss (at
Signal Loss Status
register) at
a user defined threshold. This threshold can be set to a resolution of 10 mv rms. Program the threshold by writing
the value of the voltage threshold in integer decimal format.
For example
, if channel 1 input signal loss voltage
threshold is to be 7 V
RMS
, the programmed word to the corresponding register would be 700 (2BCh).
Reference Loss Threshold
Each individual channel input reference voltage “V
REF
” is measured and the value reported to a corresponding
read register. The reference loss detection circuitry can be tailored to report a reference loss (at
Reference Loss
Status
register) at a user defined threshold. This threshold can be set to a resolution of 10 mv rms. Program the
threshold by writing the value of the voltage threshold in integer decimal format.
For example
, if channel 1 input
reference loss voltage threshold is to be 20 V
RMS
, the programmed word to the corresponding register would be
2000 (7D0h).
D/S Channel Frequency
Each individual channel Reference Frequency is measured and the value reported to a corresponding read
register. The input reference frequency is reported to a resolution of 1 Hz. The output is in integer decimal format.
For example
, if channel 1 input excitation is 400 Hz, the output measurement word from the corresponding
register would be 400.