INSTALLATION INSTRUCTIONS
5. Piping and wrapping
Bundle the tubing, connecting cable, and drain
hose with tape securely, evenly as shown in
Fig.12
Because the condensed water from rear of the
indoor unit is gathered in ponding box and is
piped out of room. Do not put anything else in
the box.
Indoor unit
Connective
pipe
Pipe room
Ponding box
Wrapping belt
Connective
cable
Drain hose
Fig.12
Connect the indoor unit first, then the
outdoor unit.
Do not allow the piping to let out from the
back of the indoor unit.
Be careful not to let the drain hose slack.
Heat insulated both of the auxiliary piping.
Be sure that the drain hose is located at
the lowest side of the bundle. Locating at
the upper side can cause drain pan to
overflow inside the unit.
Never intercross nor intertwist the power
wire with any other wiring.
Run the drain hose sloped downward to
drain out the condensed water smoothly.
CAUTION
Install the outdoor unit on a rigid base to
prevent increasing noise level and vibration.
Determine the air outlet direction where the
discharged air is not blocked. In the case that
the installation place is exposed to strong wind
such as a seaside, make sure the fan operating
properly by putting the unit lengthwise along the
wall or using a dust or shield plates.
Specially in windy area, install the unit to prev-
ent the admission of wind. If need suspending
installation, the installation bracket should
accord with technique requirement in the
installation bracket diagram.
The installation wall should be solid brick,
concrete or the same intensity construction, or
actions to reinforce, damping supporting should
be taken. The connection between bracket and
wall, bracket and the air conditioner should be
firm, stable and reliable.
Be sure there is no obstacle which block
radiating air.
Strong
wind
Fig.13
.
.
.
. .
.
.
.
.
.
.
.
.
.
.
.
.
...
..
.
.
.
.
.
.
.
. .
.
Outdoor unit installation
Outdoor installation precaution