5
compressor runs cooler and
provides longer service. The
ventilation openings on your air
compressor are necessary to
maintain proper operating
temperature. Do not place rags
or other containers on or near
these openings.
ADDITIONAL REGULATORS
AND CONTROLS
Since the air tank pressure is
usually greater than that which
is needed, a regulator is
employed to control the air
pressure ahead of any
individual driven device.
Separate air transformers which
combine the function of air
regulation, moisture and dirt
removal should be used where
applicable.
DOING THE FOLLOWING
BREAK-IN PROCEDURES.
SERIOUS DAMAGE MAY
RESULT IF THE FOLLOWING
BREAK-IN INSTRUCTIONS ARE
NOT CLOSELY FOLLOWED.
THIS PROCEDURE IS
REQUIRED BEFORE THE AIR
COMPRESSOR IS PUT INTO
SERVICE, OR AFTER
REPLACING THE CHECK
VALVE, AND WHEN THE
PISTON OR THE CYLINDER
SLEEVE IS REPLACED.
A. Set the pressure switch to the
OFF position.
B. Plug the power cord into the
correct branch circuit receptacle.
C. Turn the drain valve (B) Fig. 4
clockwise, opening it fully, to
prevent air pressure build-up in
the tank.
D. Move the pressure switch to
ON/AUTO. The compressor will
start.
E. Run the compressor for 15
minutes. Make sure the drain
valve is open and there is no tank
pressure build-up.
F. After 15 minutes, close the
drain valve by turning the knob.
The air receiver will fill to cut-out
pressure and the motor will stop.
The air compressor is now ready
for use.
OPERATING PROCEDURES
Preparation for use:
1. Before attaching air hose or
accessories, make sure the
OFF/AUTO is set to OFF and the
air regulator is closed.
2. Attach hose and accessories.
WARNING
: Too much air
pressure causes a hazardous
risk of bursting. Check the
manufacturer's maximum
pressure rating for air tools
and accessories. The regulator
outlet pressure must never
exceed the maximum pressure
rating of the tool being used.
3. Turn the OFF/AUTO to ON
and allow tank pressure to
build. Motor will stop when
tank pressure reaches cut-out
pressure.
4. Open the regulator by
turning lock ring to unlock it
and then turning the regulator
clockwise. Adjust the regulator
to the correct pressure
setting.The compressor is
ready for use.
5. Always operate the air
compressor in well ventilated
areas; free of gasoline or other
solvent vapors. Do not operate
the compressor near a spray
gun operating area.
After Use:
6. Set the switch to OFF.
7. Lift then turn the regulator
button counterclockwise to set
the outlet pressure to zero and
finally push the button down
again to lock in place.
8. Remove the air tool or
accessory.
9. Pull ring on safety valve (I)
Fig. 5, allowing air to bleed
from the tank until tank
pressure is approximately
20psi. Release safety valve
ring.
BREAK-IN PROCEDURES
NOTE:
MAKE SURE THAT
YOU HAVE FILLED THE
CRANKCASE WITH
COMPRESSOR OIL UP TO
THE CENTER DOT OF THE
OIL LEVEL AS DESCRIBED IN
THE MAINTENANCE
SECTION AND THAT ALL
ASSEMBLY INSTRUCTIONS
ABOVE HAVE BEEN
FOLLOWED BEFORE
Содержание 42801
Страница 9: ...feedback natitools com 89042801 ...
Страница 10: ...feedback natitools com ...