background image

5

[email protected]

1-800-348-5004

Spark Plug Maintenance:

1.Disconnect Spark Plug Wire 
from end of plug. Clean out 
debris from around Spark Plug.

2.Using the spark plug wrench 
provided, remove the Spark 
Plug.

3.Inspect the Spark Plug:If the 
electrode is oily, clean it using a 
clean, dry rag. If the electrode 
has deposits on it, polish it using 
emery paper. If the white 
insulator is cracked or chipped, 
the Spark Plug needs to be 
replaced.

4.When installing a new Spark 
Plug, adjust the Plug’s gap to the 
specification on the Technical 
specification chart and in the 

FIGURE N

FIGURE O

illustration below. Do not pry 
against the electrode or the 
insulator, the Spark Plug can be 
damaged. (See Figure O.)

5.Install the new Spark Plug or 
the cleaned Spark Plug into the 
Engine. Gasket-style: Finger-
tighten until the gasket contacts 
the cylinder head, then about 
1/2-2/3 turn more.
Non-gasket-style: Finger-tighten 
until the plug contacts the head, 
then about 1/16 turn more.

Cleaning, Maintenance, and 
Lubrication Schedule: Engine

Note: This maintenance 
schedule is intended solely as a 
general guide. If performance 
decreases or if the Engine 
operates unusually, check 
systems immediately. The 
maintenance needs of this 
Engine will differ depending on 
factors such as temperature, air 
quality, fuel quality, and other 
factors.

Note: These procedures are in 
addition to the regular checks 
and maintenance explained as 
part of the regular operation of 
the Engine.

After Initial 25 Operation Hours:
1.Change unleaded gasoline 
and 2-cycle oil fuel mixture.

Every 25 Operation Hours 
Thereafter:
1.Clean/replace Air Filter 
Element.

2.Inspect/clean Spark Plug.

Every 50 Operation Hours:
1.Change unleaded gasoline 
and 2-cycle oil fuel mixture.

Every 100 Operation Hours:
1.Replace Spark Plug.
Replace Air Filter Element.

Note: All maintenance 
procedures scheduled for 20, 50, 
and 100 operation hours should 
be performed at least yearly.

Every 300 Operation Hours:
1.Clean Fuel Tank and 
Carburetor assembly.
2.Clean carbon build-up from 
Combustion.

Maintenance and Cleaning 
Schedule: Generator

Before Every Use:
1.Check to make sure all bolts 
and nuts are tight.
2.Check for any damage to the 
Generator.If damaged, do not 
use until repaired by a qualified 
service technician.

After Every Use:
1.Allow the unit to completely 
cool. Then clean the exterior of 
the Generator with a clean cloth.

Содержание 1250 XLT

Страница 1: ...ehold power supply 4 Do not smoke while refueling the generator Do not overflow the fuel when refueling the generator Stop the generator before refueling Gasoline is flammable and the sparks may cause it to ignite Keep the generator at least 3 feet away from flammable materials 5 Electrical equipment including any lines and plug connections should be insulated 6 The circuit breakers should be matc...

Страница 2: ...ator to a grounding rod not included The grounding rod must be an earth driven copper or brass rod electrode which can adequately ground the generator See Figure A PRE START CHECKS 1 Check to make sure the Engine Power Switch is in its OFF position See Figure C CAUTION Your Warranty is VOID if the Engine s Fuel Tank is not filled with the proper mixture 50 1 of unleaded gasoline and 2 cycle oil be...

Страница 3: ...rator must not exceed the rated maximum power of the unit 2 Always reduce the load if the AC Circuit Breaker turns off Once the load is reduced press the Breaker to reset the Generator and continue operation See Figure I 3 Allow the Engine to run at no load until warm approx 3 minutes after each start up to allow the Engine to stabilize 4 To fill the Fuel Tank first wipe off the Fuel Tank Cap and ...

Страница 4: ...N 2 Remove the Air Filter Element 3 Wash the Air Filter Element in warm water and mild detergent several times Rinse Squeeze out excess water and allow it to dry completely Soak the Filter in lightweight oil briefly then squeeze out the excess oil 4 Install the new Air Filter Element or the cleaned Filter Secure the Air Cleaner Cover before use 4 Plug the power cord of the 120 volt appliance tool ...

Страница 5: ... general guide If performance decreases or if the Engine operates unusually check systems immediately The maintenance needs of this Engine will differ depending on factors such as temperature air quality fuel quality and other factors Note These procedures are in addition to the regular checks and maintenance explained as part of the regular operation of the Engine After Initial 25 Operation Hours...

Страница 6: ... or first 20 hrs every 3 months or 50 hrs every 6 months or 100 hrs every year or 300 hrs As necessary Engine oil check level x Air cleaner check x Clean x fuel filter cup Clean x spark plug check clean x gas tank check gas level x Clean x Run generator premix gas out prior to long periods of storage ...

Страница 7: ...park plug and pull the start handle several times to air out the chamber Reinstall spark plug and set choke to start position IGNITION SPARK RELATED Spark plug wire not connected 1 securely Spark plug electrode wet or dirty 2 Incorrect spark plug gap 3 Spark plug wire or spark plug broken 4 Incorrect spark timing or faulty ignition 5 system IGNITION SPARK RELATED Connect spark plug wire properly 1...

Страница 8: ...replace fuel tank cap 2 Properly adjust idle speed 3 Have qualified technician diagnose and 4 service engine Engine knocks Old or low quality gasoline 1 Engine overloaded 2 Incorrect spark timing deposit buildup 3 worn engine or other mechanical problems Fill fuel tank with fresh 89 octane 1 unleaded gasoline and 2 cycle oil mixture Do not exceed equipment s load rating 2 Have qualified technician...

Страница 9: ...9 feedback natitools com 1 800 348 5004 Troubleshooting Guide Generator Unit ...

Страница 10: ...y or indirectly to misuse abuse negligence or accidents repairs or alterations or a lack of maintenance NAT shall in no event be liable for death injuries to persons or property or for incidental special or consequential damages arising from the use of our products To receive service under warranty the original manufacturer part must be returned for examination by an authorized service center Ship...

Страница 11: ...8807517 12 12 1250 XLT GENERATOR Model 51769 m For customer service call 1 800 348 5004 or email 11 feedback natitools co Parts List ...

Страница 12: ...sher 4 62 Piston 1 17 Flat washer 4 63 Piston pin fender ring 2 18 Seal ring 1 64 Cylinder seal cushion 1 19 Bolt 3x8 2 65 Piston ring 1 20 Adjustable speed fork 1 66 Cylinder block 1 21 Adjustable speed lever 1 67 Cylinder head gasket 1 22 Bolt 6x40 1 68 Cylinder head 1 23 Seal ring 1 69 Sparkle plug 1 24 Press spring 1 70 Flange bolt 6x100 2 25 Adjustable speed piece 1 71 Double head bolt 6x113 ...

Страница 13: ...120V 8807517 12 12 m 13 feedback natitools co Wire Diagram ...

Отзывы: