background image

3

[email protected]

1-800-348-5004

4.Turn the Engine Choke Lever 
to its "CHOKE" position. Set the 
Choke Lever in the "RUN" 
position when starting a warm 
Engine. (See Figure E.)

5.Then turn the Engine Power 
Switch to its "ON" position. (See 
Figure F.)

6.Grasp the Recoil Starter 
Handle and pull slowly until 
resistance is felt. While holding 
the Handle, allow the Starter 
Rope to rewind slowly. Then, pull 
the Starter Handle with a rapid, 
full arm stroke. Once again while 
holding the Handle, allow the 
Rope to rewind slowly. Repeat as 
necessary, until the Engine 
starts. (See Figure G.) warm up 
for five minutes after starting with 
no electrical load.

5. After the Engine starts and 
warms up, slowly move the 
Choke Lever  to its "RUN" 
position. (See Figure H.)
IMPORTANT: Allow the Engine 
to run at 

6. no load until warm (approx. 3 
minutes) after each start-up to 
allow the Engine to stabilize.

EQUIPMENT OPERATION

1.The total combined load 
through the outlet on the 
Generator must not exceed the 
rated maximum power  of the 
unit.

2.Always reduce the load if the 
AC Circuit Breaker turns off. 
Once the load is reduced, press 
the Breaker to reset the 
Generator and continue 
operation. (See Figure I.)

3.Allow the Engine to run at no 
load until warm (approx. 3 
minutes) after each start-up to 
allow the Engine to stabilize.

4.To fill the Fuel Tank, first wipe 
off the Fuel Tank Cap and the 
surrounding area. (See Figure 
C.)

5.Unscrew, and remove the Fuel 
Tank Cap  (See Figure C.)

6.Remove the Strainer and 
remove any dirt and debris. 
Then replace the Strainer. (See 
Figure C.)

7.Fill the Fuel Tank to about 1 
inch under the fill neck of the 
Tank with the pre-mixed 
unleaded gasoline/2-cycle oil 
mixture.

8.Then replace the Fuel Tank 
Cap (See Figure C.)

TO START THE ENGINE

1.Check to make sure the 
Engine Switch is in its  "OFF" 
position.

2.IMPORTANT:Make sure to 
unplug any load from the 
Generator before starting to any 
appliance, tool, or equipment.

3.Turn the Engine Fuel Switch to 
its "ON" position. (See Figure D.)

"ON"

FIGURE D

Choke

Lever

"CHOKE"

"RUN"

FIGURE E

ON

FIGURE F

FIGURE G

Choke

Lever

"CHOKE"

"RUN"

FIGURE H

RESET
OFF

FIGURE I

CIRCUIT
BREAKER

Содержание 1250 XLT

Страница 1: ...ehold power supply 4 Do not smoke while refueling the generator Do not overflow the fuel when refueling the generator Stop the generator before refueling Gasoline is flammable and the sparks may cause it to ignite Keep the generator at least 3 feet away from flammable materials 5 Electrical equipment including any lines and plug connections should be insulated 6 The circuit breakers should be matc...

Страница 2: ...ator to a grounding rod not included The grounding rod must be an earth driven copper or brass rod electrode which can adequately ground the generator See Figure A PRE START CHECKS 1 Check to make sure the Engine Power Switch is in its OFF position See Figure C CAUTION Your Warranty is VOID if the Engine s Fuel Tank is not filled with the proper mixture 50 1 of unleaded gasoline and 2 cycle oil be...

Страница 3: ...rator must not exceed the rated maximum power of the unit 2 Always reduce the load if the AC Circuit Breaker turns off Once the load is reduced press the Breaker to reset the Generator and continue operation See Figure I 3 Allow the Engine to run at no load until warm approx 3 minutes after each start up to allow the Engine to stabilize 4 To fill the Fuel Tank first wipe off the Fuel Tank Cap and ...

Страница 4: ...N 2 Remove the Air Filter Element 3 Wash the Air Filter Element in warm water and mild detergent several times Rinse Squeeze out excess water and allow it to dry completely Soak the Filter in lightweight oil briefly then squeeze out the excess oil 4 Install the new Air Filter Element or the cleaned Filter Secure the Air Cleaner Cover before use 4 Plug the power cord of the 120 volt appliance tool ...

Страница 5: ... general guide If performance decreases or if the Engine operates unusually check systems immediately The maintenance needs of this Engine will differ depending on factors such as temperature air quality fuel quality and other factors Note These procedures are in addition to the regular checks and maintenance explained as part of the regular operation of the Engine After Initial 25 Operation Hours...

Страница 6: ... or first 20 hrs every 3 months or 50 hrs every 6 months or 100 hrs every year or 300 hrs As necessary Engine oil check level x Air cleaner check x Clean x fuel filter cup Clean x spark plug check clean x gas tank check gas level x Clean x Run generator premix gas out prior to long periods of storage ...

Страница 7: ...park plug and pull the start handle several times to air out the chamber Reinstall spark plug and set choke to start position IGNITION SPARK RELATED Spark plug wire not connected 1 securely Spark plug electrode wet or dirty 2 Incorrect spark plug gap 3 Spark plug wire or spark plug broken 4 Incorrect spark timing or faulty ignition 5 system IGNITION SPARK RELATED Connect spark plug wire properly 1...

Страница 8: ...replace fuel tank cap 2 Properly adjust idle speed 3 Have qualified technician diagnose and 4 service engine Engine knocks Old or low quality gasoline 1 Engine overloaded 2 Incorrect spark timing deposit buildup 3 worn engine or other mechanical problems Fill fuel tank with fresh 89 octane 1 unleaded gasoline and 2 cycle oil mixture Do not exceed equipment s load rating 2 Have qualified technician...

Страница 9: ...9 feedback natitools com 1 800 348 5004 Troubleshooting Guide Generator Unit ...

Страница 10: ...y or indirectly to misuse abuse negligence or accidents repairs or alterations or a lack of maintenance NAT shall in no event be liable for death injuries to persons or property or for incidental special or consequential damages arising from the use of our products To receive service under warranty the original manufacturer part must be returned for examination by an authorized service center Ship...

Страница 11: ...8807517 12 12 1250 XLT GENERATOR Model 51769 m For customer service call 1 800 348 5004 or email 11 feedback natitools co Parts List ...

Страница 12: ...sher 4 62 Piston 1 17 Flat washer 4 63 Piston pin fender ring 2 18 Seal ring 1 64 Cylinder seal cushion 1 19 Bolt 3x8 2 65 Piston ring 1 20 Adjustable speed fork 1 66 Cylinder block 1 21 Adjustable speed lever 1 67 Cylinder head gasket 1 22 Bolt 6x40 1 68 Cylinder head 1 23 Seal ring 1 69 Sparkle plug 1 24 Press spring 1 70 Flange bolt 6x100 2 25 Adjustable speed piece 1 71 Double head bolt 6x113 ...

Страница 13: ...120V 8807517 12 12 m 13 feedback natitools co Wire Diagram ...

Отзывы: