Installing the interface modules
41
CAUTION
Risk of equipment damage
Always handle interface modules by the edges, or use the
levers, where applicable.
CAUTION
ACHTUNG
Risiko eines Geräteschadens
Berühren Sie Interfacemodule immer an den Rändern, oder
verwenden Sie die Hebel, sofern vorhanden.
Prerequisites
•
Ensure you have a Phillips #2 screwdriver.
Installing a Small Module
Use the procedure in this section to install a Small Module in the Secure
Router 4134. You can install Small Modules in slots 1, 2, 3, and 4.
ATTENTION
Slot 2 of the Secure Router 4134 supports only one port of any WAN data Small
Module. If you install a 2-port Small Module in Slot 2, and use the Small Module
for data connections, one port only is functional (port 1).
This limitation also applies to the 2-port T1/E1 and ISDN BRI Small Modules if
they are configured for voice traffic: only port 2/1 is functional. This limitation
does not apply to FXS or FXO voice modules.
If you are working with 2- or 4-port FXS or FXO Small Modules, ensure
you read the safety messages related to the FXS and FXO interface
modules. See
“Foreign Exchange Station (FXS) Interface Modules” (page
17)
and
“Foreign Exchange Office (FXO) Interface Modules” (page 18)
.
For instructions to install a Small Module in the Voice Carrier Medium
Module, see
“Installing a Small Module in the Voice Carrier Medium
Module” (page 43)
.
Procedure steps
Step
Action
1
Use a Phillips screwdriver to remove the slot cover plate from the
slot in which you will install the module.
2
Align the module with the slot and the slot module guides.
3
Slide the module into the chassis until its connector panel
touches the chassis back panel.