Page 166 of 290
NT5D33 and NTRB34 Line-side E1 Interface Cards
553-3001-105
Standard 5.00
June 1999
Alarms
The MMI may be used to activate alarms for the following E1-link
conditions: excessive bit-error rate, frame-slip errors, out-of-frame,
loss-of-signal, and blue alarm. Pre-set thresholds and error durations trip LEI
alarm notifications. For descriptions of each of these E1-link alarm
conditions, see “Performance counters and reporting” on page 184. For
instructions on how to set alarm parameters, see “Set Alarm” on page 171.
For information on accessing alarm reporting, see “Display Alarms” on
page 182, “Display Status” on page 183 and “Display Performance” on
page 185.
Two levels of alarm severity exist for bit errors. Different threshold and
duration settings must be established for each level. When the first level of
severity is reached (alarm level 1), the MMI will cause the external alarm
hardware to activate, the RED ALARM LED on the faceplate will be lit, an
alarm message will be displayed on the MMI terminal, and an entry will be
created in the alarm log and printed to the MMI port. When the second level
of severity is reached (alarm level 2), the MMI will perform all functions
performed at alarm level 1, and, in addition, the LEI will enter
line-conditioning mode. In this mode, the LEI will send either “on-hook” or
“off-hook” signals for all 30 ports to the Meridian 1, depending on how the
dip switch for line processing is set (dip switch 2, position 6). See Table 38
on page 150.
If the MMI detects E1-link failures for any of the other conditions monitored
(out-of-frame, excess frame slips, loss-of-signal, and blue alarm condition),
the LEI automatically performs all alarm level 2 functions. The MMI also
sends a yellow alarm to the distant end LTU. Alarms may be set to self-clear
when the alarm condition is no longer detected. See “Set Clearing” on
page 175.
All alarms activated produce a record in the alarm log. The alarm log
maintains records for the most recent 100 alarms, and can be displayed,
printed, and cleared. The alarm log displays or prints the alarms in descending
chronological order, beginning with the most recent alarm. Notifications in
the alarm log include the date and time of the alarm’s occurrence.
Содержание NT1R20
Страница 2: ......
Страница 4: ...iv 553 3001 105 Standard 5 00 June 1999 iv ...
Страница 12: ...xii Contents 553 3001 105 Standard 5 00 June 1999 ...
Страница 76: ...Page 52 of 290 Description 553 3001 105 Standard 5 00 June 1999 ...
Страница 98: ...Page 74 of 290 NT1R20 Off Premise Station Analog Line Card 553 3001 105 Standard 5 00 June 1999 ...
Страница 154: ...Page 130 of 290 NT5D11 Line side T1 Interface Card 553 3001 105 Standard 5 00 June 1999 ...
Страница 216: ...Page 192 of 290 NT5D33 and NTRB34 Line side E1 Interface Cards 553 3001 105 Standard 5 00 June 1999 ...
Страница 264: ...Page 240 of 290 QPC192 Off Premise Extension OPX Analog Line Card 553 3001 105 Standard 5 00 June 1999 ...
Страница 276: ...Page 252 of 290 QPC452 Basic 500 2500 Analog Line Card 553 3001 105 Standard 5 00 June 1999 ...
Страница 302: ...Page 278 of 290 QPC789 16 port Message Waiting Analog Line Card 553 3001 105 Standard 5 00 June 1999 ...
Страница 306: ...Page 282 of 290 List of terms 553 3001 105 Standard 5 00 June 1999 ...
Страница 314: ...Page 290 of 290 553 3001 105 Standard 5 00 June 1999 ...
Страница 315: ......