Page 146 of 290
NT5D33 and NTRB34 Line-side E1 Interface Cards
553-3001-105
Standard 5.00
June 1999
Line Supervisory Signaling protocol
The LEI is capable of supporting loop start or ground start call processing
modes. Make your selection for this dip switch position based on what type
of line signaling your CPE equipment supports.
Address of LEI to the MMI
The address of the LEI to the MMI is made up of two components:
1
the address of the card within the shelf
2
the address of the shelf in which the card resides.
These two addresses are combined to create a unique address for the card. The
MMI reads the address of the card within the shelf from the card firmware;
the address of the shelf must be set by this dip switch.
The shelf address dip switch can be from 0-15, 16 being the maximum
number of Line-side E1 IPE shelves (a maximum of 64 LEI cards) capable of
daisy chaining to a single MMI terminal. For clarity and ease, it is
recommended that this address be set the same as the address of the peripheral
controller identifier in overlay 97 for type: XPE. However, this is not
mandatory, and, since the dip switch is limited to 16, this will not always be
possible.
E1 framing
The LEI is capable of interfacing with LTU equipment either in CRC-4 or
FAS only framing mode. Make your selection for this dip switch position
based on what type of framing your LTU equipment supports.
E1 Coding
The LEI is capable of interfacing with LTU equipment using either AMI or
HDB3 coding. Make your selection for this dip switch position based on the
type of coding your LTU equipment supports.
Line supervision on E1 failure
This setting determines in what state all 30 LEI ports will appear to the
Meridian 1 in case of E1 failure. Ports can appear to the Meridian 1 as either
in the “on-hook” or “off-hook” states on E1 failure.
Содержание NT1R20
Страница 2: ......
Страница 4: ...iv 553 3001 105 Standard 5 00 June 1999 iv ...
Страница 12: ...xii Contents 553 3001 105 Standard 5 00 June 1999 ...
Страница 76: ...Page 52 of 290 Description 553 3001 105 Standard 5 00 June 1999 ...
Страница 98: ...Page 74 of 290 NT1R20 Off Premise Station Analog Line Card 553 3001 105 Standard 5 00 June 1999 ...
Страница 154: ...Page 130 of 290 NT5D11 Line side T1 Interface Card 553 3001 105 Standard 5 00 June 1999 ...
Страница 216: ...Page 192 of 290 NT5D33 and NTRB34 Line side E1 Interface Cards 553 3001 105 Standard 5 00 June 1999 ...
Страница 264: ...Page 240 of 290 QPC192 Off Premise Extension OPX Analog Line Card 553 3001 105 Standard 5 00 June 1999 ...
Страница 276: ...Page 252 of 290 QPC452 Basic 500 2500 Analog Line Card 553 3001 105 Standard 5 00 June 1999 ...
Страница 302: ...Page 278 of 290 QPC789 16 port Message Waiting Analog Line Card 553 3001 105 Standard 5 00 June 1999 ...
Страница 306: ...Page 282 of 290 List of terms 553 3001 105 Standard 5 00 June 1999 ...
Страница 314: ...Page 290 of 290 553 3001 105 Standard 5 00 June 1999 ...
Страница 315: ......