NN10078-911 SN06.2 Preliminary 02.03 March 2004
81
Copyright © 2004, Nortel Networks
Nortel Networks Confidential
where
slot_no
is the slot number on the ENET shelf (0 to 38)
Example of a MAP screen:
Verify that the ENET card in the back of the slot has PEC
9X40DA.
13
If dual-shelf connections are used, locate the second ENET card
by typing
>LOCATE 1 <slot_no>
and pressing the Enter key.
where
slot_no
is the slot number on the ENET shelf (0 to 38)
Example of a MAP screen:
Verify that the ENET card in the back of the slot has PEC
9X40DA.
14
Go to the card level of the ENET by typing
>CARD <slot_no>
and pressing the Enter key.
where
slot_no
is the slot number on the ENET card (0 to 38)
Example of a MAP screen:
Request to LOCATE ENET Plane:0 Shelf:00 Slot:14 submitted
Request to LOCATE ENET Plane:0 Shelf:00 Slot:14 passed.
Site Flr RPos Bay_id Shf Description Slot EqPEC
HOST 01 A02 ENC 000 39 ENET:0:00:14 14 9X35BA FRNT
HOST 01 A02 ENC 000 39 ENET:0:00:14 14 9X40DA BACK
Request to LOCATE ENET Plane:1 Shelf:00 Slot:14 submitted
Request to LOCATE ENET Plane:1 Shelf:00 Slot:14 passed.
Site Flr RPos Bay_id Shf Description Slot EqPEC
HOST 01 A02 ENC 000 13 ENET:1:00:14 14 9X35BA FRNT
HOST 01 A02 ENC 000 13 ENET:1:00:14 14 9X40DA BACK