![Nortel IW SPM IP Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/nortel/iw-spm-ip/iw-spm-ip_manual_1707047011.webp)
IW SPM IP Fault Management
Nortel Networks Confidential
11
Copyright © 2004, Nortel Networks
Log SPM300 Format
Log SPM300 reports a device fault.
Log SPM300 format
SPM 300 ** <mmmdd hh:mm:ss> <ssdd> TBL Device Fault Report
Location: <NODE> <DEVICE>
Status : Alarm Raised
Problem Description: Critical
7A: Check messaging: Inactive CEM to RM loopback test timeout.
Action : Refer to NTPs for Alarm Clearing Procedures.
Cardlist : No Cardlist Available.dlist Available.
Trouble Reason
Indicates the reason for the trouble condition.
Trouble Detail
Provides more information about the trouble condition.
Log NODE303 format
Field
Description
Log SPM300 format
Field
Description
TBL
Indicates the trouble condition with the node.
Device Fault Report
Indicates that the information to follow is a device fault report
on the indicated device.
Location
Indicates the location of the peripheral event and device to
which the event applies.
Status
Indicates whether the alarm is raised or cleared
Problem
Description
Indicates the type of fault (Info, Non-critical, Critical) along with
the information on which CEM reported the fault and a text
string indicating what fault occurred.
Action (User)
Indicates the suggested user action.
Cardlist
Indicates the cards to be replaced.