background image

Technical Specifications

Table 1:

BayStack 460-24T-PWR Power over Ethernet Switch technical specifications (continued)

Electrical specifications

Input voltage: 

100 to 240 VAC at 47 to 63 Hz

Input power consumption: 

400 W maximum

Input volt amperes rating: 

440 VA maximum

Input current: 

4.5 A @ 100 VAC, 2.25 A @ 240 VAC

Maximum thermal rating:

575 BTU/hr

Physical specifications

Weight: 

5.8 kg (12.76 lb)

Height: 

7.04 cm (2.77 in.)

Width: 

43.82 cm (17.25 in.)

Depth: 

38.35 cm (15.1 in.)

Environmental specifications

Operating temperature: 

0° to 40° C (32° to 104°F)

Storage temperature: 

–25° to 70° C (-13° to 158°F)

Operating humidity: 

85% maximum relative humidity, non-condensing

Storage humidity: 

95% maximum relative humidity, non-condensing

Operating altitude: 

Up to 3024 m (10,000 ft.)

Storage altitude: 

Up to 3024 m (10,000 ft.)

Safety agency approvals 

UL listed (UL 60950)

CUL (CAN/CSA-22.2 No. 60950)

CB certificate and report with all national deviations (IEC 60950/EN60950)

Electromagnetic emissions summary

Meets the following standards:

United States:

FCC CFR47 PART 15, SUBPART B, Class A

Canada:

ICES-003, ISSUE-3, Class A

Australia/New Zealand:

AS/NZ 3548: 1995/A1:1997/A2; 1997, Class A

Japan:

VCCI-V-3/02.04/ Class A

Taiwan:

CNS 13438, Class A

Europe:

EN 55022-1998/A1:2000 Class A

EMC Directive: 89/336/EEC:

Directly published in the EMC Directive of 89/336/EEC with 

Modification 92/31/EED, 93/13/EC

EN 61000-3-2: 2000

EN 61000-3-3: 1995/A1:2001

Global: 

CISPR 22-1997/A1:2000, Class A

Electromagnetic immunity 

Global:

CISPR 24:1997/A1:2001

Europe: 

EN55024:1998/A1:2001

9

Содержание BayStack 460-24T-PWR

Страница 1: ... devices badge readers Figure 1 The switch has all of the features of the BayStack Business Policy Switch such as advanced Quality of Service QoS and high resiliency with the addition of Power over Ethernet capability It enables enter prise customers to power devices while maintaining connectivity to standard 10 100 Mbps Ethernet devices such as BayStack 460 24T PWR Power over Ethernet Switch Nort...

Страница 2: ...for a separate cable connecting the IP device to a power outlet Significant space and cost savings Traditionally a mid span patch panel device connects to a standard Ethernet switch and the device sends power over standard UTP cat 5 cable In essence two units are needed for Power over Ethernet capability In contrast the BayStack 460 Switch integrates standard LAN switch functionality with the powe...

Страница 3: ...witch or across a stack Protocol based VLANs allow switch ports to be assigned to a broadcast domain based on the protocol information within the packet These VLANs can localize broadcast traffic and assure that the specified protocol type packets are sent only to the protocol based VLAN ports Shared VLAN SVL and individual VLAN IVL learning is supported With SVL support all VLANs in the switch sh...

Страница 4: ...ce RADIUS for switch security management IP Manager List limits access to the manage ment features of the BayStack 460 Switch by a defined list of IP addresses providing greater network security and manageability SNMPv3 provides user authentication and data encryption for higher security It also offers secure configuration and monitoring For even greater security the BayStack 460 Switch also suppo...

Страница 5: ...power systems please visit their Web site at www intergynes com For information on how to purchase NES DC power system please e mail Invensys at us_dc_quotes energy invensys com or nes quotes energy invensys com Network management On box management Network management begins with the device The BayStack 460 Switch supports four groups of Remote Monitoring RMON on all ports and is SNMPv3 compliant T...

Страница 6: ...er specific service offerings which can be implemented to address specific and unique customer requirements Queuing function The BayStack 460 Switch provides network availability for mission critical applications devices and users This is done by classifying prioritizing and marking LAN IP traffic using up to eight hardware based IP service class queues on the Gigabit uplink ports based on the fol...

Страница 7: ...ng of different levels of service by limiting traffic throughput at the ingress incoming port of the BayStack 460 Switch For example if a port is set to certain speeds such as 10 Mbps all traffic under 10 Mbps on that port will pass and traffic that exceeds 10 Mbps on that same port is dropped Service providers will find this especially useful to control bandwidth to their customers IP traffic sha...

Страница 8: ...ltimode 550m 1805 ft fiber optic cable The BayStack 450 1GBIC MDA supports the following GBICs 1000BASE SX Uses shortwave 850 nm fiber optic connectors to connect devices over multimode 550 m or 1 805 ft fiber optic cable 1000BASE LX Uses longwave 1 300 nm fiber optic connectors to connect devices over single mode 5 km or 3 1 mi or multimode 550 m or 1 805 ft fiber optic cable 1000BASE XD Uses sin...

Страница 9: ...dity 95 maximum relative humidity non condensing Operating altitude Up to 3024 m 10 000 ft Storage altitude Up to 3024 m 10 000 ft Safety agency approvals UL listed UL 60950 CUL CAN CSA 22 2 No 60950 CB certificate and report with all national deviations IEC 60950 EN60950 Electromagnetic emissions summary Meets the following standards United States FCC CFR47 PART 15 SUBPART B Class A Canada ICES 0...

Страница 10: ...or GBIC 1550nm Wavelength 40km LC connector AA1419030 1 port 1000BASE CWDM Small Form Factor GBIC 1570nm Wavelength 40km LC connector AA1419031 1 port 1000BASE CWDM Small Form Factor GBIC 1590nm Wavelength 40km LC connector AA1419032 1 port 1000BASE CWDM Small Form Factor GBIC 1610nm Wavelength 40km LC connector AA1419033 1 port 1000BASE CWDM Small Form Factor GBIC 1470nm Wavelength 70km LC connec...

Страница 11: ... 800 4 NORTEL or 1 800 466 7835 from anywhere in North America Nortel Networks the Nortel Networks logo and the globemark design are trademarks of Nortel Networks All other trademarks are the property of their owners Copyright 2003 Nortel Networks All rights reserved Information in this document is subject to change without notice Nortel Networks assumes no responsibility for any errors that may a...

Отзывы: